background image

20

 

Rev. 1/23

 

 

GB784SH INSTALLATION TOOL S/N: 1008 AND ABOVE 

 

PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.

 

 

FIRST AID MEASURES

 

 

Eye: 

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.

 

Skin: 

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material 

from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

 

Ingestion: 

No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice.

 

Inhalation: 

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to 

fresh air. Get medical attention if coughing or respiratory discomfort occurs.

 

Note to Physicians: 

In an accident involving high

-

pressure equipment, this product may be injected under the skin. Such an accident 

may result in a small, sometimes bloodless, puncture wound. However, because of its driving force, material injected into a fingertip can 

be deposited into the palm of the hand. Within 24 hours, there is usually a great deal of swelling, discoloration, and intense throbbing 

pain. Immediate treatment at a surgical emergency center is recommended.

 

 

FIRE

 

 

Leaks/ruptures in high pressure system using materials of this type can create a fire hazard when in the vicinity of ignition sources (e.g. 

open flame, pilot lights, sparks, or electric arcs).

 

 

FLAMMABLE PROPERTIES:

 

Flashpoint: 

(Cleveland Open Cup) 178 °C (352 °F) Minimum

 

 

EXTINGUISHING MEDIA: 

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

 

 

PROTECTION OF FIRE FIGHTERS:

 

Fire Fighting Instructions: 

This material will burn although it is not easily ignited. See Section 7 for proper handling and storage. For fires 

involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self

-

contained breathing 

apparatus.

 

Combustion Products: 

Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including 

carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

 

 

ACCIDENTAL RELEASE MEASURES

 

 

Protective Measures: 

Eliminate all sources of ignition in vicinity of spilled material. 

 

Spill Management: 

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, 

surface water or groundwater. Clean up spill as soon as possible. Use appropriate techniques such as applying non

-

combustible 

absorbent materials or pumping. Where feasible and appropriate, remove contaminated soil. Place contaminated materials in disposable 

containers and dispose of in a manner consistent with applicable regulations.

 

 

ECOLOGICAL INFORMATION

 

 

Waste disposal: 

In accordance with all environmental regulations applicable to your area.

 

 

Spillage: 

Prevent entry into drains, sewers and water course. Soak up with diatomaceous earth or other inert material. Store in 

appropriate container for disposal.

 

 

Ecotoxicity: 

This material is expected to be harmful to aquatic organisms and may cause long

-

term adverse effects in

 

the aquatic environment. The ecotoxicity hazard is based on an evaluation of data for the components or a similar material.

 

 

HANDLING

 

 

Precautionary Measures: 

DO NOT USE IN HIGH PRESSURE SYSTEMS in the vicinity of flames, sparks and hot surfaces. Use only in 

well ventilated areas. Keep container closed. Keep out of the reach of children.

 

General Handling Information: 

Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of 

water.

 

Static Hazard: 

Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this 

hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the 

potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash 

filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate 

mitigating procedures.

 

 

 

DISPOSAL CONSIDERATIONS

 

 

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal. Place 

contaminated materials in containers and dispose of in a manner consistent with applicable regulations.

 

DEXRON® III OIL SAFETY DATA

 

Содержание GB784SH

Страница 1: ...R YOU GB784SH ORIGINAL INSTRUCTIONS INSTALLATION TOOL 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www gagebilt com GAGE BILT MADE in USA S...

Страница 2: ...y 3 Description 4 Description of Functions 5 Safety Warnings 6 Principle of Operation 7 How to Set Up 8 How to use the GB784SH 9 Maintenance 10 Filling 11 Bleeding 12 Troubleshooting 13 Overhaul 14 17...

Страница 3: ...buyer or subsequent user in repairing or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Sel...

Страница 4: ...has a 875 22 2 mm fastener setting stroke and a rated pull load of 2 650 lbs 11 79 kN with 90 psi 6 2 bar of air pressure at the air inlet The GB784SH installation tool operates on 90 to 100 psi 6 2...

Страница 5: ...OR ALL OTHER SERIAL NUMBERS DESCRIPTION OF FUNCTIONS Air Inlet Actuator Actuator Lever Assembly Handle Assembly Head Cylinder Assembly Air Line Handle Split Hydraulic Hose Return Manifold Handle Hydra...

Страница 6: ...he case of interruption of energy supply 6 Use only lubricants recommended by the manufacturer 7 Avoid unsuitable postures as it is likely for these positions not to allow counteracting of normal or u...

Страница 7: ...bly is also moving down forcing hydraulic oil up and into the front side of the head cylinder causing the piston to move to the rear of the head cylinder The internal components of the attached nose a...

Страница 8: ...all warnings and cautions WARNING It is required that eye protection hearing protection and safety boots be worn at all times while handling this equipment WARNING The users or the user s employer mu...

Страница 9: ...based on their application Ensure there is adequate clearance for tool and operator s hands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed ma...

Страница 10: ...ation below Verify that hydraulic hose fittings and couplings air and electrical connections are secure Tighten Replace or Repair if necessary Cycle the tool several times to assure there are no leaks...

Страница 11: ...ole marked P Remove front button head cap screw 402482 and stat o seal S572 from head cylinder 784221 See bleeding procedure pg 12 7 In one continuous squeeze force oil into manifold handle 745303 unt...

Страница 12: ...875 22 2 mm Min using instructions a thru c and diagrams below We recommend using calipers a With the actuator lever assembly released 704343 check dimension A b While holding actuator lever assembly...

Страница 13: ...y 743142 may be blocked or damaged Hole diameter should be 028 71 mm Clear and size or replace 3 NO OPERATION WHEN ACTUATOR LEVER ASSEMBLY 704343 IS DEPRESSED a Tool seized due to mechanical failure o...

Страница 14: ...commended during reassembly to prevent tearing or distorting of o rings The disassembly and re assembly procedure can be accomplished by utilizing the following instructions and parts list on pgs 14 1...

Страница 15: ...BLY AIR 704130 1 Apply Teflon tape onto threads of actuator assembly air 704130 one to two wraps 2 Thread the actuator assembly air 704130 all the way into handle machined 784309 with fingers 3 Insert...

Страница 16: ...1 uniformly to 40 inch lbs 4 52 Nm to prevent leakage around the gasket 745124 HEAD 1 Clamp the shift piston 784125 into the large hole of clamp wrench assembly 784201 locating on a polished surface T...

Страница 17: ...serted into top of power cylinder 743131 To reassemble the handle assembly 744129 1 Reverse the above procedure being certain that all o rings are properly lubricated before installation Torque packin...

Страница 18: ...18 Rev 1 23 GB784SH INSTALLATION TOOL S N 1008 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST...

Страница 19: ...19 Rev 1 23 GB784SH INSTALLATION TOOL S N 1008 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST...

Страница 20: ...ic compounds will be evolved when this material undergoes combustion ACCIDENTAL RELEASE MEASURES Protective Measures Eliminate all sources of ignition in vicinity of spilled material Spill Management...

Страница 21: ...ress Actuator assembly air 704130 and hold Gage point 1 should be flush with face of front cap as shown Release the actuator assembly air 704130 4 To increase gage protrusion turn adjuster knob clockw...

Страница 22: ...of stroke setting gage 784159 over threads on head piston until it seats on pistons shoulder gage point 2 must line up with front of tool as shown in figure A 3 Depress and hold actuator assembly air...

Страница 23: ...lace sleeve assembly A over collet and head piston Slip knurled cap over the sleeve assembly and hand tighten onto end of installation tool head RIVET NOSE DIAMETER ASSEMBLY A B 3 32 3U 681 25 188 348...

Страница 24: ...45263 Sold Separately Grip Gage 269G3 For CHERRYMAX and CHERRYLOCK rivets Sold Separately Grip Gage GB105093 For NAS LOCKBOLTS and blind fasteners Sold Separately Air Bleeder Assembly 704153 Sold Sepa...

Страница 25: ...PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS Alternative Styles Sold Separately GB784SR Stroke 875 22 2 mm Hand held weight 3 00 lbs 1 36 kg Pull load 2 650 11 79 kN GB784 Stroke 875 22 2 mm...

Страница 26: ...26 Rev 1 23 GB784SH INSTALLATION TOOL S N 1008 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS Split Riveter Tool Backpacks For 5ft hose Split System Tools Sold Separately...

Страница 27: ...27 Rev 1 23 GB784SH INSTALLATION TOOL S N 1008 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS This page intentionally left blank...

Страница 28: ...RKS OF CHERRY AEROSPACE POP IS A REGISTERED TRADEMARK OF EMHART TEKNOLOGIES LOCTITE IS A REGISTERED TRADEMARK OF HENKEL CORPORA TION TEFLON IS A REGISTERED TRADEMARK OF E I DUPONT DE NEMOURS CO SLIC T...

Отзывы: