background image

12

 

Rev. 1/23

 

 

GB713SR

-

8 INSTALLATION TOOL 

S/N: 1024 AND ABOVE 

 

PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.

 

 

1.

 

Ensure pin and lever on lever assembly (724017) has been removed. 

Stand handle assembly (744129) on floor, stretch hose and 

head cylinder assembly (713127) upward and lay flat on a table or bench. When bleeding tool always keep the head cylinder 

 

 

assembly (713127) higher than the handle assembly (744129).

 

 

2.

 

Remove button head cap screw (402482) and stat

-

o

-

seal (S572) from manifold

-

handle (744303) hole marked #3. Attach air bleeder 

assembly (704153) to manifold

-

handle (744303) hole marked #3 in an upright position.

 

 

3.

 

Connect the tool to air supply and cycle tool ten times holding the actuator assembly

-

air (704130) down for 2 

-

 3 seconds between 

cycles to remove any air from the tool. 

 

 

4.

 

Disconnect air supply. Remove air bleeder assembly (704153) from manifold

-

handle (744303) and replace with button head cap 

screw (402482) and stat

-

o

-

seal (S572) and torque to 35 

-

 40 inch lbs. (3.95 

-

 4.52 Nm).

 

 

5.

 

Remove button head cap screw (402482) and stat

-

o

-

seal (S572) from hole marked #4 manifold

-

head assembly (744306) and attach 

air bleeder assembly (704153) in an upright position. 

 

 

6.

 

Connect air supply. Cycle tool ten times removing any air bubbles.

 

 

7.

 

Disconnect air supply. Remove air bleeder assembly (704153) and replace button head cap screw (402482) and stat

-

o

-

seal (S572) 

and torque to 35 

-

 40 inch lbs. (3.95 

-

 4.52 Nm).

 

 

8.

 

Connect air supply. Cycle tool ten times and check stroke of 

.760” (19.3 

mm) using instructions a thru c and diagrams below. We 

recommend using dial calipers.

 

 

 

 

a. With the actuator assembly

-

air (704130) released, check dimension (A).

 

 

 

 

b. Holding actuator assembly

-

air (704130) check dimension (B).

 

 

 

 

c. Subtract dimension (A) from dimension (B). If stroke is not consistent within 1/64" (.396 mm) repeat bleeding steps until 

 

 

    stroke met.

 

 

 

For your consideration, Gage Bilt offers a depth gage (Pt.# A

-

1935) to help simplify and more accurately check your tool stroke. Please 

 

contact Gage Bilt for more information.

 

 

9.

 

Disconnect air supply.

 

 

10.

 

Re

-

attach lever and pin to lever assembly (724017).

 

 BLEEDING PROCEDURE:

 

Note: 

 

 

• 

Air Bleeder Assembly (704153) (sold separately) is required.

 

 

* FILLING & BLEEDING VIDEO AVAILABLE AT:

 http://www.gagebilt.com/rivet_tools_videos.php

   

Images may not reflect actual tool.

 

Hole marked #4 on Manifold 

Head Assembly (744306)

 

*located on far side*

 

Hole marked #3 on 

 

Manifold Handle (744303)

 

Air Bleeder 

 

Assembly 

(704153)

 

 

WARNING:  

Do not cycle tool without air bleeder assembly (704153), or the screw and stat

-

o

-

seal, installed in tool head. Severe 

 

 

 

personal injury could result.

 

 

 

WARNING:

 

Use CAUTION when removing screws, air bleeder assembly (704153) and fill bottle (745263). Hydraulic oil may be 

 

 

 

  under pressure.

 

 

CAUTION: 

Before filling handle assembly (744129), air piston assembly (744121) should be all the way down. 

 

  

CAUTION: 

When forcing piston rod assembly (744136) downward, with head cylinder assembly (713127) removed, hydraulic oil will 

 

 

 

 

eject forcibly from handle assembly .

 

 

CAUTION:

 

When bleeding tool, ensure tubing is free from kinks or other obstructions.

 

Содержание GB713SR-8

Страница 1: ...YOU GB713SR 8 INSTALLATION TOOL ORIGINAL INSTRUCTIONS 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www gagebilt com GAGE BILT MADE in USA S...

Страница 2: ...echnical Specifications 4 Description of Functions 5 Warnings 6 Principle of Operation 7 How to set up the GB713SR 8 8 How to use the GB713SR 8 9 Maintenance and Hydraulic Thread Preparation 10 Fillin...

Страница 3: ...EXW our plant any goods providing defective from faulty workmanship or materi al for 1 year from date of shipment Said warranty to remain in effect if and only if such goods are used in accordance wit...

Страница 4: ...blind rivets This tool s unique split system provides the operator with a lightweight ergonomic tool The handle and head assembly when held in hand weighs 2 50 lbs 1 13 kg The entire split handle ins...

Страница 5: ...ASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS DESCRIPTION OF FUNCTIONS Actuator Deflector Air Line Hydraulic Hose Pull Air Inlet Image may not reflect actual tool Hanger Bleed Screw Bleed Screw A...

Страница 6: ...is not fitted 10 Due to the tool weight it is recommended safety shoes be worn during operation 11 It is recommended tool be operated not more than 50 out of every 60 minutes where prolonged use is e...

Страница 7: ...y the piston rod assembly connected to the air piston assembly is also moving down forcing hydraulic oil up and into the front side of the head cylinder causing the piston to move to the rear of the h...

Страница 8: ...ners WARNING Operator MUST read and understand all warnings and cautions WARNING It is required that eye protection hearing protection and safety boots be worn at all times while handling this equipme...

Страница 9: ...se based on their application Ensure there is adequate clearance for tool and operator s hands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed...

Страница 10: ...for damage or wear Any repair should be done by qualified personnel trained on Gage Bilt procedures WARNING Excessive contact with hydraulic oil and lubricants should be avoided WARNING Maintenance p...

Страница 11: ...o that the hole marked 4 on manifold handle 744303 is to the top Set head cylinder assembly 713127 over a small bucket or can Completely fill up fill bottle 745263 6 Remove button head cap screw 40248...

Страница 12: ...supply Cycle tool ten times and check stroke of 760 19 3 mm using instructions a thru c and diagrams below We recommend using dial calipers a With the actuator assembly air 704130 released check dime...

Страница 13: ...SSED a Tool seized due to mechanical failure or damaged parts 4 OIL LEAKAGE a DO NOT OPERATE WITH OIL LEAKING FROM TOOL HIGH PRESSURE OIL MAY CAUSE SEVERE PERSONAL INJURY b Any oil leaking externally...

Страница 14: ...tact with an o ring Use of Lubriplate Gage Bilt part no 402723 or other lubricant is recommended during reassembly to prevent tearing or distorting of o rings The disassembly and re assembly procedure...

Страница 15: ...UATOR ASSEMBLY AIR 704130 1 Apply Teflon tape onto threads of actuator assembly air 704130 one to two wraps 2 Thread the actuator assembly air 704130 all the way into manifold head assembly 744306 wit...

Страница 16: ...m bottom of handle assembly 744129 6 After removal of air piston assembly 744121 slide piston rod assembly 744136 back up to the end of its travel Using packing plug wrench assembly 704150 remove pack...

Страница 17: ...17 Rev 1 23 GB713SR 8 INSTALLATION TOOL S N 1024 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST...

Страница 18: ...18 Rev 1 23 GB713SR 8 INSTALLATION TOOL S N 1024 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST...

Страница 19: ...nic compounds will be evolved when this material undergoes combustion ACCIDENTAL RELEASE MEASURES Protective Measures Eliminate all sources of ignition in vicinity of spilled material Spill Management...

Страница 20: ...352 61 45N 751B 54RA 4 5N 751A 43OS 5mm 6N 751 23 6N 352 61 6N 751C 54RA 4 6N 751A 43OS 5 32 5N 751 23 5N 352 61 45N 751B 54RA 4 5N 751A 43OS 3 16 6N 751 23 6N 352 61 6N 751C 54RA 4 6N 751A 43OS 1 4...

Страница 21: ...OTHER SERIAL NUMBERS Alternative Styles Sold Separately GB713SH Stroke 760 19 3 mm Hand held weight 2 50 lbs 1 1 kg Entire tool weight 7 50 lbs 3 4 kg Pull load 4 500 20 0 kN GB713 Stroke 760 19 3mm...

Страница 22: ...arately Catcher Bag Stem 704214 Sold Separately Air Bleeder Assembly 704153 Sold Separately Grip Gage 269G3 For CHERRYMAX and CHERRYLOCK fasteners Sold Separately Grip Gage GB105093 For NAS LOCKBOLTS...

Страница 23: ...23 Rev 1 23 GB713SR 8 INSTALLATION TOOL S N 1024 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS This page intentionally left blank...

Страница 24: ...Riveter Tool Backpacks For 5ft hose Split System Tools Sold Separately DEXRON IS A REGISTERED TRADEMARK OF GENERAL MOTORS CORPORATION LOCTITE IS A REGISTERED TRADEMARK OF HENKEL CORPORATION TEFLON IS...

Отзывы: