manualshive.com logo in svg
background image

REV.  8/14 

 

HYDRAULIC THREAD PREPARATION 

 

IMPORTANT:

 

Be sure to use thread sealant on all hydraulic fittings, Loctite® 30534 or similar Teflon® infused pipe  

 

 

   dope is recommended. 

CAUTION:

 

Teflon tape is an excellent thread sealer, however, if it is not proper-

 

 

   ly applied, pieces may enter the hydraulic system and cause malfunction and damage. Use 1 1/2 wraps  

 

 

   of tape on each thread. Cut off all loose tape ends. Tighten until fitting feels snug and then go 1/2 to a  

 

 

   full turn past  that point. 

CAUTION:

 Over tightening can easily distort the threads. 

DESCRIPTION 

        

                                                                              

 The GB706LGP hydraulic installation tools designed specifically for the efficient installation of 3/16" LGP® 
lockbolts. It weighs just over 3 lbs. 

(1.36 kg) 

and can be operated in any position with one hand. It has a .500 

(12.7mm) rivet setting stroke and a rated pull load of 5800 lbs. 

(25.8 kN).

 

 
The  GB706LGP  installation  tool  operates  on  hydraulic  pressure  developed  by  the  GB940  Powerunit  set  at 
5600 psi 

(386.1  bar) 

maximum PULL pressure and 2400 psi 

(165.5  bar) 

maximum RETURN pressure. The 

tool  comes  equipped with  12  feet  of  hydraulic hoses (206119),  hydraulic  coupling-male  (585047),  hydraulic 
coupling-female (585038), electric actuator (240122) and electric cord (206136).  

MAINTENANCE 

 

WARNING

Excessive contact with hydraulic oil and lubricants should be avoided.

 

 

WARNING:

 

Maintenance personnel 

MUST

 

read and understand all warnings and cautions.

 

 

WARNING

Be sure powerunit is disconnected before cleaning or when replacing worn or damaged 

                      components. Severe personal injury may occur if power source is not disconnected.

 

 

The performance of any tool depends upon the practice of good maintenance. 
Following these minimal requirements for service and care will extend the life of your tool. 
 

*Only use a hydraulic power source equipped with relief valves and pressures set within 

 

specified limits.  

 Consult Powerunit Manual for procedure to set Pull and Return pressures. 
*Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor. 
*Do not use as a hammer to force fasteners into holes or otherwise abuse tool. 
*Proper care by operators is necessary in maintaining full productivity and reducing down  
  time.  

 

    

*Check tool, all hoses and all couplings daily for damage or air/hydraulic leaks. Tighten or 

    

  replace (if necessary). 

  

*To replace super-grip jaw ass

=

y (30601-CS):

 

 

1. Remove cap (705112) from back of piston ass

=

y (705210).  

  

 

2. Remove spacer (60843) and old super-grip jaw ass

=

y (30601-CS).  

  

 

3. Insert new super-grip jaw ass

=

y (30601-CS) and spacer (60843).  

  

 

4. Apply removable Loctite

7

 to the threads of cap (705112).  

   

 

5. Thread cap (705112) approximately 3/4 into back of piston ass

=

y (705210).  

  

 

6. Insert spent pintail into super-grip jaw ass

=

y (30601-CS) and continue threading cap 

 

 

    (705112) until spent pintail ratchets through super-grip jaw ass

=

y (30601-CS). 

  

 

7. Let Loctite setup. 

 

Содержание GB706LGP

Страница 1: ...TOOL GAGE BILT Inc 44766 Centre Court 586 226 1500 Clinton Twp MI 48038 586 226 1505 Fax e mail solutions gagebilt com www gagebilt com GAGE BILT MADE IN U S A GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E MAIL US FOR DISTRIBUTOR NEAR YOU ...

Страница 2: ... stroke 500 12 7mm Rated pull load 5800 lbs 25 8 kN Noise level 81 5 dB A Vibration Tested No hazards found TABLE OF CONTENTS Description Page Warnings 3 Principle of Operation and How to use the GB706LGP 4 Description Maintenance and Hydraulic Thread Preparation 5 Parts Lists 6 Troubleshooting and Overhaul 7 EU Conformity and Warranty 8 2 94 74 7mm 2 20 55 7mm OPTIONAL HOSE ATTACHMENT 1 17 Ø 29 7...

Страница 3: ...is required to use hearing protection A test was carried out in a simulated work environment where the background level was 73 2 dB A In this condition the max level was 81 5 dB A Therefore it is required where prolonged use hearing protection be used CAUTION Do not use beyond the design intent WARNING Tool must be maintained in a safe working condition at all times and examined on a regular daily...

Страница 4: ...ded and may be dangerous CAUTION Do not use beyond design intent 1 Set power supply to the recommended pressure 5 600 psi 386 1 bar for the pull and 2 400 psi 165 4 bar for the return 2 Connect hydraulic coupling male 585047 hydraulic coupling female 585038 and male connector 585044 to power supply WARNING Ensure hydraulic hoses are securely connected to avoid possible hose whipping 3 To ensure pi...

Страница 5: ...oided WARNING Maintenance personnel MUST read and understand all warnings and cautions WARNING Be sure powerunit is disconnected before cleaning or when replacing worn or damaged components Severe personal injury may occur if power source is not disconnected The performance of any tool depends upon the practice of good maintenance Following these minimal requirements for service and care will exte...

Страница 6: ...12 585044 MALE CONNECTOR 206119 HYDRAULIC HOSE 12 2 403431 REDUCER BUSHING 2 706214 ADAPTER 30601 CS SUPER GRIP JAW ASSY 206118 SCREW 585038 HYDRAULIC COUPLER FEMALE 706103 CAP PISTON 60843 SPACER 585047 HYDRAULIC COUPLER MALE 403764 O RING 401080 BACK UP RING 204304 SWIVEL ASSEMBLY NOTES 1 700338 includes 401106 403802 402373 2 2 705210 includes 403810 401114 3 206115 includes 405758 401105 40583...

Страница 7: ...RNING Disconnect tool from its power source before performing overhaul WARNING Tool must be maintained in a safe working condition at all times and examined on a regular daily basis for damage or wear Any repair should be done by qualified personnel trained on Gage Bilt procedures WARNING When operating repairing or overhauling tool wear approved eye protection Do not look in front of tool or rear...

Страница 8: ...e liable for incidental or consequential damages or for damages incurred by the buyer or subsequent user in repairing or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Seller is not notified in writing of any rejections or defects within 6 months after the receipt of the material by the cust...

Отзывы: