P a g e
|
16
•
Fuses...
For DC & AC systems, refer to the manufacturer’s specification for the overcurrent
protection device (OCPD) rating & quantity.
•
Array setbacks...
Comply with the fire code for setbacks required for the solar array from the
edges of the roof. The DecoTech™ Solar System requires a minimum of one row of shingles to be
installed at the eave and the ridge. It is recommended to keep 3' (914 mm) from the rake edge
(to roll out the underlayment beyond the footprint of the array on the sides).
•
Concentrated sunlight…
Artificially concentrated sunlight must
not
be directed onto the solar
module assembly.
•
Mounting hardware…
The DecoTech™ Module Assembly is intended to be mounted to a roof
using only the hardware provided. If other mounting means are employed, this may affect the UL
listing, the fire classification rating, and the GAF warranty.
•
Design loading…
The DecoTech™ Module Assembly with SolarWorld laminates has been
evaluated by UL for a maximum positive design loading of 50 lb/ft
2
(244 kg/m
2
).
•
Fire classification
… The DecoTech™ Solar System has been rated as Class A for resistance to
external fire exposure per UL 2703 when used with both the following materials on a roof:
1.
Leak Barrier: One ply of self-adhered StormGuard® Film-Surfaced Leak Barrier
and
2.
Slip Sheet: One ply of VersaShield® SOLO™ Fire-Resistant Slip Sheet, mechanically
fastened with staples
For roof mounting, the acceptability of the completed assembly, including the fire resistance of
the underlying components of the roof, shall be considered per local fire codes.
•
Solar trackers…
The DecoTech™ Module Assembly has
not
been evaluated for use on a solar
tracker.
•
Nonstructural component…
These products have been evaluated for serving as a nonstructural
component of a building only. They are not intended to serve as a primary component of the
building's exterior surface. The supporting structure (integrated racking) provided with these
systems can only support the solar laminate.
•
PV laminate specific...
The DecoTech™ Solar Module Assembly may be used to ground and/or
mount a PV laminate complying with UL 1703 only when the specific module has been evaluated
for grounding and/or mounting in compliance with the included instructions.
•
Wiring accessibility…
These products and associated wiring must
not
be accessible from the
interior space of the building. NEC procedures for installation of wiring must be followed.
•
Roof obstructions…
Do
not
install any portion of the solar array over any roof obstructions,
plumbing, or attic vents. Do
not
attempt to cut or modify the solar module assembly to
accommodate any roof projections. Explore whether a roof obstruction can be removed or
relocated to another area of the roof.