background image

INSTALLATION INSTRUCTIONS

 

1.- WARNING  

Please read these instructions before installing or using this appliance for the first time. 

 

The warranty of the heater will not cover any damage caused by non observance of any of these instructions. 

 

This guide must be kept and given to any new owner. 

 

Please check that the voltage in the rating label fits the power supply. 

 

Any reinstallation should be carried out by trained personnel. 

 

The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects. 

 

DO NOT USE THIS HEATER TO DRY CLOTHES. 

 

The surfaces of this heater can be hot, so young children should not be left unsupervised in the vicinity of the heater. 

 

Neither the connecting cable nor any other object must come into contact with the hot unit. 

 

Do not cover this heater at any time. 

  The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the 

appliance. They also protect the heater from overheating; therefore, it is essential that at no time are they covered. 

 

This heater should be switched off at the isolating switch before any repair work is carried out. 

 

The thermal radiator should not be installed just below an electrical socket. 

 

The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls. 

 

The installation must be carried out in accordance with the current electrical regulations. 

 

The heater is fitted with a flexible cable size 3 x 1.00 mm2 for electrical connection. It may be used to connect the heater to the fixed wiring of 
the premised through a suitable connection box positioned adjacent to the heater.  

 

The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least  3 mm. 

 

If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special 
tools are necessary. 

 

This appliance must be earthed. 

 

All models are supplied with an electrical interrupt cut-out. This will switch off the heater if, for any reason, it overheats. Should the cut-out 
operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically. 

 

The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater. 

  This heater is filled with a precise quantity of special oil. Repairs requiring the opening of the oil container are only to be made by the 

manufacturer or his service agent who should be contacted if there is an oil leakage. 

 

Regulations concerning the disposal of oil when scrapping the appliance have to be followed.  

 

Modelo 

RF

4

P

         

RF

6

P

        

 RF

8

       

RF

10

P

        

RF

12

P

        

RF

14P        

 

                 

 RF4E

        

RF

6

E

         

RF8E

         

RF10E

          

 

RF12E

       RF14E

 

TYPE 

Manual - Thermostat only                                                    Digital - 24hr / 7 Day Timer & Thermostat 

MODULES 

4

 

6

 

8

 

10

 

12           14

 

                                4

 

6

 

8

 

10          12            14  

 

(cm) 

41.5

     

 

  

57.5 

        

73.5 

        

89.5

         

105.5

      121.50                      4

1.5 

        

57.5 

        

73.5

         89.5

 

       105.5       121.5

D (cm) 

10 (plus 2.5 cm separated from the wall) 

H (cm) 

58 

WEIGHT (kg) 

9.5         13.5         17.5        21.5          25.5        29.5                         9.5          13.5         17.5        21.5         25.5         29.5

 

INPUT 

500W

       

 750W

        

 1000W

        

 

1250W        

1500W 

      2000W 

 

                        

500W 

       

750W 

        

1000W

       

 1250W

       

1500W

        2000W

 

VOLTAGE 220-240V~ 

 
2.- INSTRUCTIONS ON INSTALLATION 

 

 
- Open the carton at the indicated side. The screws are in the accessories bag. Turn the carton upside down to allow the heater to stand. Check 
that it is the correct model and that it is in good condition. 
- To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material 
as furniture, curtains etc. See figure . 
 
 

 

 

 

 

 

 

 

 
 

shelf

minimum 15cm

 

minimum 10cm 

Closest 

object to 

the left 

end 

minimum15cm 

Closest 
object to the 
right end 

minimum 25cm 

 
 

Содержание RF4P

Страница 1: ...IGNER RADIATORS RF4P RF4E RF6P RF6E RF8P RF8E RF10P RF10E RF12P RF12E RF14P RF14E INSTALLATION INSTRUCTIONS AND USER GUIDE Please read these instructions before installing or using this appliance for the first time ...

Страница 2: ... a double pole isolating switch having a contact separation of at least 3 mm If the flexible power cable for this unit is damaged it may only be replaced by a repair workshop recognised by the manufacturer as special tools are necessary This appliance must be earthed All models are supplied with an electrical interrupt cut out This will switch off the heater if for any reason it overheats Should t...

Страница 3: ...e heater maintains the set temperature with the temperature selector dial Moon mode on the heater maintains a temperature 3ºC lower than the one set with the temperature selector dial The studs and screws are in the accessories bag Hung the unit on the hooks of the brackets By turning the screw the metallic square will go downwards retaining the heater Repeat this on the other bracket Use the heat...

Страница 4: ...y of the 48 intervals of 30 minutes of the day SWITCHING ON THE HEATER AND SETTING THE TIME Turn the mode selector dial to P position and press the key more than two seconds The display will show the time intermittently Set the minutes by pressing and keys and press the Set the hours the same way Press once more the key to store the time If at any time it is necessary to set the time press the key...

Страница 5: ...d both luminous indicators will be off Press the key to go to the next interval The display will show 00 30 intermittently and again press one of the three keys 7 to allocate SUN MOON or OFF frost protection from 00 30h to 01 00h or press key directly if the existing temperature level is ok Repeat these steps allocating the desired temperatures levels over the 24 hours of the day Press the key at ...

Страница 6: ... six seconds This will restore the factory default settings KEYBOARD LOCK Press the 7 key more than six seconds and the keyboard will be locked The display will show and the controller will keep on working internally To unlock the keyboard press again the 7 key more than six seconds 4 CLEANING AND MAINTENANCE Clean and dust with a dry soft cloth only when the unit is disconnected and cold Do not u...

Страница 7: ...WIRING sensor controller sensor controller MODELS RF E R heating element Ts safety cut out C three way selector MODELS RF P R heating element Ts safety cut out C three way selector ...

Отзывы: