background image

screen part 2.

Settings of switched outputs EXIT1: 

In the main menu you find “Set exit 1” = Settings output exit 1. Push the ENTER button to 
get one level deeper into the menu. Than push again to “choose function”. The following 
functions are available:

Ex = disabled

= Output disabled

Ex = T1 heat

= Output sensor 1 heat

Ex = T1 cool

= Output sensor 1 cool

Ex = Rh humidify

= Output sensor 1 humidify/moisturise

Ex = Rh dehumidi

= Output sensor 1 dehumidify/drying

Ex = T2 heat 

= Output sensor 2 heat

Ex = T2 cool

= Output sensor 2 cool

Ex = timer

= Output timer

Scroll with UP / DOWN buttons to the desired function and confirm with ENTER. If a 
function has already been selected, you can use "set value" to change the values. If you 
like to switch to another function, select the new function in"Set exit 1". Change the values 
or confirm the new function with the SAVE / EXIT button.

Disabled:

This function turns off the output.

Output Sensor 1 heat:

This function is measuring the air temperature and can be to connected a heater. In the 
submenu you can make the following settings: 

page 10 of 15

Choose function

Ex1= S1 heat
Ex1= S1 cool
Ex1= S2 humidify
Ex1= S2 dehumidi
Ex1= S3 heat
Ex1= S3 cool
Ex1= timer

Ex1= disabled

Exit 1  Sensor 1
Heat day  24.0C°
Heatnight 24.0C°

Hyst.    -02.0C°

Содержание 16A

Страница 1: ...art 2 7 Main screen part 3 7 Main menu 7 Submenu ventilator settings 8 Settings of switched outputs EXIT1 10 Disabled 10 Output Sensor 1 heat 10 Output sensor 1 cool 11 Output sensor 1 humidify moistu...

Страница 2: ...tage 230V 50Hz Depending on the country the maximum power rating of the power cord is variable VDE L typ max 16A Schuko VDE F type max 16A France VDE E type max 13A Switzerland VDE U type max 13A Engl...

Страница 3: ...keys you don t have to confirm with ENTER the values get stored with SAVE EXIT All values get stored in an internal memory and are also after a power failure or prolonged disconnection available Time...

Страница 4: ...2 5 Temperature LED 6 Exit 1 LED 7 Humidity LED 8 Day night LED 9 Alarm LED 10 Exit 2 LED 11 UP arrow 12 DOWN arrow 13 SAVE EXIT 14 ENTER 15 Powersupply 16 Sensor cable for temperature and humidity on...

Страница 5: ...Menu structure page 5 of 15...

Страница 6: ...Function diagram page 6 of 15...

Страница 7: ...or 1 max T2 Temperature sensor 2 max Alarms of underrun minimum values T1 Temperature sensor 1 min RH Humidity sensor 1 min T1 Temperature sensor 2 min Confirm with the SAVE EXIT button an alarm The 9...

Страница 8: ...Set temperature Temperature setting 2 Set humidity Humidity setting 3 Fan settings Ventilator Setting Scroll with the UP DOWN keys to display the below information 1 Fan day Ventilation day 2 Fan nigh...

Страница 9: ...upply air fan don t have a minimum speed value and will turn off when the temperature and humidity undercuts the set value By setting of the minimum speed value at the exhaust fan you avoid odours esc...

Страница 10: ...utput timer Scroll with UP DOWN buttons to the desired function and confirm with ENTER If a function has already been selected you can use set value to change the values If you like to switch to anoth...

Страница 11: ...the cooling capacity becomes 24 0 C 2 0 C 26 0 C and by reaching 24 0 C is off again This contact will remain off until the value rises above 26 0 C Output sensor 1 humidify moisturise The procedure i...

Страница 12: ...to reach the selection menu Set Exit 1 To delete a program step set the time back to 00 00 00 00 00 When you have finished programming the Exit 1 press SAVE EXIT to return to the main menu Settings o...

Страница 13: ...r Here you will see the current value of the light sensor this occurs in daytime almost 100 As darker it is as lower is this value Set the switching threshold press again ENTER the value begins to bli...

Страница 14: ...ery 5minutes to your USB memory stick Push ENTER button the value begins to blink change the value with the UP DOWN buttons save it with SAVE EXIT General limitations All firmware versions support BOM...

Страница 15: ...Confirm with ENTER The controller reset all the data back to the original factory settings except time and date settings page 15 of 15...

Отзывы: