background image

 

Page 2 

 

Contents 

 

  

 

 

 

 

 

 

 

 

 

 

 

Page 

 
 Overview ………………………………………………………………………….. 

 
The Radio System ……………………………………………………………….. 

4

 

 
 The TrackSide R/C Control Board ……………………………….………...…..  

  
Installation ……………………………………………………….…….………….  

 
 Automated Station Stops ………………………………………………………..  

 
Operation …………………..……………………………………..……….……… 

 
Transmitter Command Summary ……………………………………..………..  

 
Trouble Shooting  ………………………………….…………...…..……..……..  

11 

 
User Programming ………………………….....……..……………………..…… 

12 

 
Two Track Operation …………………………………………………………….  

14 

 
Adding Wireless Reed Switch ………………………………………………….  

14 

 
Specifications ……………………..……..…………………………………..…… 

15 

 
Meanwell Power Supplies ……………………………………………………….  

16 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание TrackSide

Страница 1: ...vision C Updated 6 1 2021 Operation and Installation Manual G Scale Graphics 5860 Crooked Stick Dr Windsor CO 80550 970 581 3567 GScaleGraphics comcast net www GScaleGraphics net Revision K Updated 6...

Страница 2: ...e TrackSide R C Control Board 4 Installation 5 Automated Station Stops 6 Operation 7 Transmitter Command Summary 9 Trouble Shooting 11 User Programming 12 Two Track Operation 14 Adding Wireless Reed S...

Страница 3: ...can pass up to 10 amps of current from the power supply to your track That is more than enough to handle one or more locomotives pulling a full train Typical current draw for one locomotive motor is a...

Страница 4: ...of track The TrackSide R C Control Board The TrackSide base station houses a circuit board which is a combination control board and radio transceiver Transmitter commands control a powerful and silen...

Страница 5: ...assumed that power to the system will be switched on off at the power supply Any DC power supply with a regulated output between 7 and 25 VDC will work Bridgewerks and Crest Switching power supplies a...

Страница 6: ...tion The distance from the reed switch to the stop de pends on the speed of the loco and the station stop decel rate set in user pa rameter 1 Once you have established the desired setup save the loco...

Страница 7: ...less than what it takes to make the loco move you will eliminate the delay in getting the loco moving Note All locos have different min speeds so this may only useful when always running the same loco...

Страница 8: ...ck radio range You will likely not want to use this all the time to save TX batteries This func tion can be activated using User programming parameter 13 Fuses If you are blowing fuses due to derailme...

Страница 9: ...ming Enter Throttle Programming mode by holding down the 2nd Slower and Stop buttons until the LED in side the Trackside base station starts flashing Use Faster Slower Buttons to control speed 0 to 10...

Страница 10: ...two track mode the throttle programming save recall speed and toggle rate and interactive remote functions are disabled Speed will change at the User Programmed rate set in Parameter 0 of each base un...

Страница 11: ...peed setting to a lower value The locos runs in reverse at power up Reverse the wires at the track output The loco won t run as fast as I like even though I keep trying to increase the speed setting M...

Страница 12: ...ed switch at terminals SS and COM initiates a station stop This parameter allows you to control the per centage of time that station stops occur e g at the 50 setting after crossing the reed switch 10...

Страница 13: ...gramming The new option will now be active Exit Programming Mode To exit programming mode hold down the Program button for 5 secs then turn off TrackSide power To exit programming mode without saving...

Страница 14: ...s Momentum or your choice but both units should be the same 4 Place the Track 2 label on your base unit Your throttle momentum is now determined by User Parameter 4 so set that as desired Adding the W...

Страница 15: ...als IN 7VDC min to 25VDC max less than 1V p p ripple Reverse polarity protection prevents damage but will not operate Track Output Terminals OUT No polarity 10 amps max at 100 duty cycle Fuse automoti...

Страница 16: ...side of the power supply for 115 VAC U S Output voltage should be 24 VDC maximum for use with the G Scale Graphics Trackside R C or Track Throttle But no adjustment should be necessary as received Cr...

Отзывы: