background image

Product Information

Our 4G GSM Alarm Pro is a standalone alarm system suitable for both indoor and outside

usage and can cover a large range from the base station to the sensors. It will alert you

using GSM technology by sending a text message and/or a phone call to your mobile

phone or land line when the sensors are broken, alerting you to a possible intrusion or

fault.

The unit is enclosed in an IP65 rated enclosure, meaning it is perfectly weathered for

outside installation and has passed testing in high heats and below freezing conditions.

GSM Module Specification

 GSM Frequency: quadband Freq 2G 900/1800/1900 / (3G) 2100 / (4G) 2600 Mhz

 Power Supply Voltage: 9 - 24 volts DC - 2 Amp Min

 Current Used in Standby Mode: 50mA Max

 IP65 Rated Enclosure for Outside Installation

 Micro 2G or 3G Simcard

 No Land Line Required

 Dimensions - L100 x W68 x H50mm

 Dimensions PCB Only - L95 x W67mm

 Sim Active Function

 Operating Temperature: -10…+40°C

 Programmed by Text Message

 Text to Text Signal Strength

 Wireless Range - Beam 50m

- Key Fob 50m

- PIR 80m

 Battery Backup

 Disable Zone Remotely

Beam Specification

Alert Distance: 100 Meters

Detection: 2 Beams Blocked Simultaneously

Battery Life: Solar Powered Charged Lithium Battery 900mah - 3 months from fully

charged. Please replace battery every two years

Dimensions: L60 x W32 x H13mm

Outdoor PIR Specification

Detection Range: 12m*12m

Pet Immunity - 20kg

Battery Life: AA Lithium Battery - 6 Months

Mount Height: 1.8m - 2.4m

Dimensions - L148 x W75 x H54mm

www.gsm-activate.co.uk

 - 01273462380 - [email protected]

Page 2

Содержание ALARM PRO 20

Страница 1: ...Page 1 MODEL ALARM PRO 20 2G GSM ALARM PRO 20 ZONES ...

Страница 2: ...olts DC 2 Amp Min Current Used in Standby Mode 50mA Max IP65 Rated Enclosure for Outside Installation Micro 2G or 3G Simcard No Land Line Required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Temperature 10 40 C Programmed by Text Message Text to Text Signal Strength Wireless Range Beam 50m Key Fob 50m PIR 80m Battery Backup Disable Zone Remotely Beam...

Страница 3: ...ween 0 up to 30 We strongly recommend that you place the unit where it can receive a signal of at lease 10 Less than this will make the unit unreliable Battery Backup In the event of a power failure the internal rechargable battery will be capable of running the unit for 24 hours It will inform you of a MAINS FAILURE by text message as well as when the power is restored with the text message POWER...

Страница 4: ...age send the text command as follows IR01 YOUR MESSAGE Default message is IR01 IR02 YOUR MESSAGE Default message is IR02 The detector will reply with the text message MESSAGE STORED By changing position 01 to 20 you can name all 20 individually paired sensors IMPORTANT PLEASE READ Your can only use a maximum of 30 characters including spaces for your customised message How to Setup Call Alerts The...

Страница 5: ... cannot be stored to another location without it being unpaired using a reset Pairing the Key Fobs Press the GREEN key option It will show 3 positions and have an X or symbol this shows whether a keyfob is paired to it Choose a location from 1 3 You will then get a prompt to PRESS KEY FOB A Press the A ONLY on your key fob This will be followed by a beep to signal it has been paired and stored to ...

Страница 6: ... Once the Alarm has been alarmed it will stay alarmed even after an alarm activation To turn the alarm off and stop further alarm messages you will have to disarm the alarm by text or key fob How to Use The Siren Output The unit has been programmed to trigger the siren for 60 seconds in the event of an alarm activation Once the text message has been received you can STOP the siren sounding by pres...

Страница 7: ...etc Once the alarm has been activated it will automatically re arm once the beam has been cleared Disabling Sensor 1 Only If you want to remove sensor 1 from operation you send the text command BEAM1 ON This will re enable sensor 1 BEAM1 OFF This will disable sensor 1 The purpose of this function is to deactivate one sensor whilst retaining the rest of the alarm system This could be for a constant...

Страница 8: ... the FAQ s on our website www gsm activate co uk Alternatively email our technical support team at technical gsm activate co uk and we will do our best to respond to your querry within 24 hours Monday Friday Quick Reference 20 07 21 GD Page 8 ...

Отзывы: