23
Owner’s Manual
BEFORE STARTING THE GENERATOR
Before attempting to start the generator, verify
the following:
⚫
The engine is filled with right and enough oil.
⚫
The generator is situated in a proper location
⚫
All appliances are disconnected from the
generator.
⚫
The generator is properly grounded.
⚫
Propane connection is securely and properly.
SWICHING FUEL SOURCES
The below assumes that the propane fuel line is already attached to the generator securely and safely.
While the unit is running simply turn the
FUEL SELECTOR
knob to the desired fuel source. If you want to switch
from gasoline to propane make sure the propane tank valve is open before you switch. When you move from
propane to gasoline shut the propane valve after you have switched to gas.
Attention please:
1, If you don't plan to use propane, close the propane tank or disconnect the generator with propane tank.
2, The engine might run roughly for few second until the gasoline in the carburetor is used up, while the fuel source is
switched from Gas to Propane.
Switch to Propane position
Switch to Gas position
(FUEL SWITCH FOR GN12000DCS/GN13000DCS )
NOTICE
When operating on LPG it is common for frost to form on
the tank and regulators. This is not an indication of a
problem. The amount of frost that forms can be affected by
the size of the container, the amount of fuel being used, the
humidity of the air and other operating conditions. In
standard use this frost may reduce flow of gas and lower
performance. If frost becomes an issue try exchanging fuel
tanks to allow the first tank to warm up. You can
also temporarily warm the tank up by pouring warm water over
the top of the propane tank.