background image

 

D1014 

- SIL 2 Repeater Power Supply Hart compatible 

G.M. International ISM0052-16 

 

Ordering information 

 

Front Panel and Features 



SIL 2 according to IEC 61508:2010 Ed. 2 for Tproof = 9 / 10 years (

10% / >10 % of total SIF). 



PFDavg (1 year) 1.05 E-04, SFF 87.01%. 



SIL 3 Systematic capability. 



2 fully independent channels. 



Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2. 



4-20 mA Input, Output Signal. 



Hart compatible. 



Input and Output short circuit proof. 



High Accuracy. 



Three port isolation, Input/Output/Supply. 



EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1 



In-field programmability by DIP Switch. 



ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, EAC-EX, UKR TR n. 898, TÜV Certifications. 



TÜV Functional Safety Certification. 



Type Approval Certificate DNV and KR for maritime applications. 



High Reliability, SMD components. 



High Density, two channels per unit. 



Simplified installation using standard DIN Rail and plug-in terminal blocks. 



250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. 

Not used 

Terminal block connections 

HAZARDOUS AREA 

SAFE AREA 

+ Input Ch 2 for 2 wire Transmitters 

- Input Ch 2 for 2 wire Transmitters 

Not used 

Not used 

+ Input Ch 1 for 2 wire Transmitters 

- Input Ch 1 for 2 wire Transmitters 

Not used 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

+ Output Ch 1 for Current Source mode or + Output Ch 1 for 
Voltage Source mode or + Output Ch 1 for Current Sink mode 

1

 

- Output Ch 1 for Current Source mode or - Output Ch 1 for 
Voltage Source mode or - Output Ch 1 for Current Sink mode 

2

 

+ Ch 1 Power Supply 12-24 Vdc 

3

 

- Ch 1 Power Supply 12-24 Vdc 

4

 

+ Output Ch 2 for Current Source mode or + Output Ch 2 for 
Voltage Source mode or + Output Ch 2 for Current Sink mode 

5

 

- Output Ch 2 for Current Source mode or - Output Ch 2 for  
Voltage Source mode or - Output Ch 2 for Current Sink mode 

6

 

+ Ch 2 Power Supply 12-24 Vdc 

7

 

- Ch 2 Power Supply 12-24 Vdc 

8

 

Model:  

D1014 

1 channel 

Power Bus enclosure 

2 channels 

/B 

 

Power Bus and DIN-Rail accessories: 
DIN rail anchor MCHP065   

DIN rail stopper MOR016 

Terminal block male MOR017 

Terminal block female MOR022 

Содержание D1014S

Страница 1: ...D1014 SIL 2 Repeater Power Supply Hart compatible ISM0052 16 D1014S D1014D INSTRUCTION SAFETY MANUAL SIL 2 Repeater Power Supply Hart compatible DIN Rail Models D1014S D1014D...

Страница 2: ...uracy 0 1 of full scale Linearity error 0 1 of full scale Supply voltage influence 0 05 of full scale for a min to max supply change Load influence 0 05 of full scale for a 0 to 100 load resistance ch...

Страница 3: ...locks 250 Vrms Um max voltage allowed to the instruments associated with the barrier Not used Terminal block connections HAZARDOUS AREA SAFE AREA Input Ch 2 for 2 wire Transmitters Input Ch 2 for 2 wi...

Страница 4: ...IB C IIA D NOTE for USA and Canada IIC equal to Gas Groups A B C D E F and G IIB equal to Gas Groups C D E F and G IIA equal to Gas Groups D E F and G For installations in which both the Ci and Li of...

Страница 5: ...SAFE AREA ZONE 2 GROUP IIC T4 NON HAZARDOUS LOCATIONS CLASS I DIVISION 2 GROUPS A B C D T Code T4 CLASS I ZONE 2 GROUP IIC T4 MODEL D1014D 14 15 3 4 1 2 RL mA mA V HHT Ch 1 Supply 12 24 Vdc Source I...

Страница 6: ...solver is configured to detect High failures and does not automatically trip on these failures this failure mode has been classified as a dangerous detected DD failure Fail Low failure mode that caus...

Страница 7: ...shed via conduit connections or another acceptable Division 2 Zone 2 wiring method according to the NEC and the CEC Not to be connected to control equipment that uses or generates more than 250 Vrms o...

Страница 8: ...esponding section as an example Connect 12 24 Vdc power supply positive at terminal 3 and negative at terminal 4 for channel 1 For Model D1014D connect 12 24 Vdc power supply positive at terminal 7 an...

Страница 9: ...allows the mA sink or source mode or Volt operating mode configuration Configuration Side A Panel View Span Trimmer CH1 Screwdriver for Trimmers 1 x 0 5 mm Dip switch configuration Vtx Adjust Ch1 Scr...

Страница 10: ...ly is the same for all channels there for don t separate the terminals because one channel remains switched off Different power supply Cut both pins of the connector to open the wiring between the ter...

Страница 11: ...llow step 1 Out 2 PS Supply _ Out 1 DMM V1 CAL In 2 V1 CAL In 1 DMM mA mA mA mA MODEL D1014D 14 15 3 4 1 2 10 11 5 6 7 8 V V Out 2 PS Supply _ Out 1 DMM V1 CAL In 2 V1 CAL In 1 DMM mA mA MODEL D1014D...

Отзывы: