Technical data

Technical data

Number of selectable zones 

1 to 216 (from 20 to 60 zone selection keys plus 6 function keys)

Typical output level   

 

300 mV

Frequency response   

 

20–20'000 Hz

Distortion 

  

 < 

1%

LOW-CUT Filter  

 

-10 dB / 100 Hz

S / N Ratio 

 

> 60 dB

Connection   

 

RJ45  (IN / OUT)

Power supply voltage  

24 VCC

Maximum absorption 24 VDC  

165 mA

Dimensions (W × H × D) 

230 × 80 × 200 mm

Net weight (without microphone)   1.6 kg 
 

Dimensions in mm

34

UK

TSC6000-EN

5.  TECHNICAL SPECIFICATIONS

No. of zones that can be selected

1 to 216

(from 20 to 60 zone selection keys plus 6 function keys)

Typical output level

300 mV

Frequency response

20÷20.000 Hz

Distortion

< 1%

LOW-CUT Filter

-10dB/100Hz

S/N Ratio

> 60 dB

Connection

RJ45 (IN/OUT)

Power supply voltage

24 Vcc

Maximum absorption @24VDC

165 mA

Size (L x H x P)

230 x 80 x 200 mm

Net weight (without microphone)

1,6 kg

Содержание VA-FMCT-500

Страница 1: ...lektronik ag will not accept any liability for damage to property and or persons arising out of incorrect use of the equipment or of procedures that do not comply with the instructions provided in thi...

Страница 2: ...e brown T568 Pin Colore 1 bianco aranc 2 arancio 3 bianco verde 4 blu 5 bianco blu 6 verde 7 bianco marro 8 marrone Pin IN OUT 1 Audio 2 Audio 3 GND 4 Non collegato Not connected 5 Non collegato Not c...

Страница 3: ...This indicates the presence of at least one zone in which the sending out of emergency messages is disabled BUSY yellow Off system free no station on calls Steady ON this indicates that another statio...

Страница 4: ...di accesso al menu di con gurazione C Tastiera selezione zone D Indicatore di stato della chiamata a viva voce spento PTT non attivato acceso PTT attivato E Tasto per invio chiamata a viva voce PTT F...

Страница 5: ...sting call hands free To send out a service message hands free to the broadcasting areas press the PTT button E and hold it down The green indicator will light up to show that the microphone is active...

Страница 6: ...y under way activated by another station or by local commandsby the system Steady ON Manual emergency activated from the station itself All the keys are active so as to enable the operator to manage t...

Страница 7: ...mergency with the EMERGENCY key all the keys turn green to indicate general pre selection press the buttons corresponding to the required zones These will remain green to con rm that they have been se...

Страница 8: ...failures press the RESET ACK key briefly The buzzer will be muted only on the station while the LED referred to the failure under way will remain ON This function is active in any status of the stati...

Страница 9: ...return to the main screen press Escape 4 1 Function key con guration This screen page enables the broadcasting zones to be associated with the function keys from F1 to F6 Using this option it will be...

Страница 10: ...ey again and digit uf ci the wording Zone name uf ci will appear Press Enter to con rm 4 Press Save changes to save the con guration Continue in the same manner for the other keys UK TSC6000 EN 4 3 Le...

Страница 11: ...if any of serial communication with the control unit to which the station is connected is also signalled on this page 3 4 Unit configuration This screen page enables the main operating parameters of...

Страница 12: ...Filter 10 dB 100 Hz S N Ratio 60 dB Connection RJ45 IN OUT Power supply voltage 24 VCC Maximum absorption 24 VDC 165 mA Dimensions W H D 230 80 200 mm Net weight without microphone 1 6 kg Dimensions...

Отзывы: