35
SB 500
SEMI-AUTO
Original Instructions -Rev.00- 2015— In compliance with the paragraph 1.7.4 of the Machine
Directive 2006/42/CE
G.B.C. Industrial Tools S.p.A.
Via Artigiani,17 – 25030 Torbiato di Adro (Bs) – Italia – Tel. + 39 030 7451154 – Fax. + 39 030 73 56 629
MALFUNCTION WARNINGS
- 1 BLINK, 1 PAUSE
= Head in wrong position for AUTO cycle launch or for the pipe
end stop lowering.
- 2 BLINKS, 1 PAUSE
= Pipe end stop is not lifted for AUTO cycle or for the head
feeding forward command.
- 3 BLINKS, 1 PAUSE
= Head end stop failure.
- 4 BLINKS 1 PAUSE
= Pipe end stop failure.
- 5 BLINKS, 1 PAUSE
= Mandrel in wrong position for the AUTO cycle launch.
- RED LIGHT ALWAYS ON
= Low cooling liquid level.