FW Murphy IntelliSpark Скачать руководство пользователя страница 12

 

Section 40 

 

00-02-0893 

2014-07-18 

10 -

 

If the user selects an engine in the data base provided in the display, the firing order will be 
known and the wiring color code will be shown on this page. If the user provides a custom 
firing order, the display will still organize the wiring and show the proper wire by color code that 
should go to each cylinder, taking into account the user-entered firing order.  

This page is useful to leave on the screen during operation. Anybody checking on the engine 
can view this page from several feet away and immediately see if all cylinders are firing 
normally.  

The BACK button takes the user back to the Spark kV page. 

Diagnostic Log Page 

The Diagnostic Log button takes the user to a page that shows if any faults have occurred.  

Figure 8.0 Diagnostic Log Page 

 

The three possible diagnostic conditions for each cylinder are displayed in a table format. Any 
occurrence of one of the three fault conditions will cause the appropriate box to be filled in red, 
and this box will remain red until the Clear Log button is pressed. This page is useful to identify 
intermittent problems. The user can see what occurred, even if it only occurred once since the 
last clearing. In figure 8.0 it shows that cylinder 1R had at least one occurrence of an open 
primary since this page was cleared. Cylinder 5R had a shorted primary, and cylinder 8R had 
an open secondary.  

The user has the option to return to the Spark kV page or to the Alarm page. 

A final comment on the diagnostic faults: Faults must occur for any two out of three 
consecutive revolutions for it to be registered. This filtering technique eliminates false reporting 
of faults. If any cylinder is detected to have a diagnostic condition that persists for two out of 
three revolutions in a row the condition is considered real. 

Содержание IntelliSpark

Страница 1: ...00 02 0893 2014 07 18 Section 40 IgnitionSystems Operation Manual...

Страница 2: ...BEFORE BEGINNING INSTALLATION OF THIS FW MURPHY PRODUCT Read and follow all installation instructions Please contact FW Murphy immediately if you have any questions...

Страница 3: ...equirements 3 Power Supply 3 Ignition Enable 3 Crank and Cam Signals 3 Operating 4 Display Functions Main Menu 4 Engine Start Up 5 Engine Run Mode 6 Spark kV Page 7 Engine View Page 9 Diagnostic Log P...

Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...efer to the Specifications section in the Installation Booklet for details Note that the system also requires a few seconds after power is applied before it is able to start firing If the system is be...

Страница 6: ...his button to be active For example if the engine is running this button will not be active System Setup This button takes the user to the passcode screen and then to the setup menu For details on wha...

Страница 7: ...s the page contents when the system is in the standby mode and is ready to start the engine In this example the timing schedule A is active and the timing is set for 10 0 degrees BTDC The Tank voltage...

Страница 8: ...s relay turns on the fuel valve the engine should start to pick up speed Figure 3 0 Cranking Engine Run Mode Once the engine RPM exceeds the Crank Run RPM the system will go into the normal run mode O...

Страница 9: ...engine spark kV page would look like The leftmost vertical bar graph shows how much kV the coil is supplying The individual cylinder graphs show what each plug requires for breakdown Underneath each b...

Страница 10: ...gy gauge will also rise tracking the tank voltage The energy gauge can provide a good indication of the auto energy control loop operating and can also be used to help determine or predict the end of...

Страница 11: ...alue Figure 7 0 Engine Block View Another feature of the engine block page is the indication of the wire color of the primary lead that should be wired to the indicated cylinder The primary harness co...

Страница 12: ...possible diagnostic conditions for each cylinder are displayed in a table format Any occurrence of one of the three fault conditions will cause the appropriate box to be filled in red and this box wi...

Страница 13: ...ce of the 1 REV pulse and the trailing edge is negative indicating the trailing edge happened after the 1 REV pulse These are normal values The CAM parameters are grayed out if the unit is programmed...

Страница 14: ...int Page The View Edit Setpoints page allows the user to observe and change several operating parameters In order to edit the user must enter a passcode These parameters can be set during standby or r...

Страница 15: ...rrect passcode has been entered and the 1 REV Position parameter has been selected for editing The Select arrows cause the gauge select pointer to scroll from gauge to gauge In the example the user ha...

Страница 16: ...eled More which will bring him to another page that gives him access to two factory set parameters Figure 12 0 Factory Setpoints These parameters are set during a final factory test They affect the kV...

Страница 17: ...the Active Shutdown would show normal shutdown and it would be saved and time stamped below the Active Shutdown line The Alarms include some shutdowns as well as detected fault conditions that are not...

Страница 18: ...screen after the user pressed the Alarm Ack Button Figure 14 0 Ignition Fault screen view In the above example the user is asked to view the Diagnostic Log Page Figure 15 0 shows the Diagnostic Log p...

Страница 19: ...ed directly This is further covered in the ignition class From this data it appears that the first and third revolutions are the compression stroke due to the higher values on these firings than on th...

Страница 20: ......

Отзывы: