19
FILL TYPE
The Fill Type parameter defines how Fills will be generated. The Fill Type can be adjusted using the
Parameter knob, or Switch A(-) or Switch B(+). Press/hold the TAP Switch to activate a Fill as long as this
switch is held.
NO FILL
– No notes will be generated when Fill is activated.
OFF STEPS
– Fill only the steps that are OFF in the Rhythm pattern.
ON STEPS
– Fill only the steps that are programmed into the Rhythm pattern.
ALL STEPS
– Fill all steps will generate a fill at the highest clock rate defined by the Time Signature
selected.
NOTE:
When the sequencer playback is stopped, selecting any parameter mode that allows you to produce a
Fill by pressing the TAP Switch, will instead allow you to use the TAP Switch to manually generate a Trigger
output with CV1 and CV2 outputs producing their respective value to write.
REC STEPS
The Record Steps parameter defines how notes will be entered into the Rhythm pattern. The REC STEPS can
be adjusted using the Parameter knob, or Switch A(-) or Switch B(+). Press/hold the TAP Switch to activate a
Fill as long as this switch is held.
RHYTHM
– New notes will be entered into the Rhythm part only when recording the Rhythm itself.
CV1
– New notes will be written into the Rhythm part when notes are recorded into the Rhythm or
CV1 part.
CV2
– New notes will be written into the Rhythm part when notes are recorded into the Rhythm or
CV2 part.
CV1 + 2
– New notes will be written into the Rhythm part when notes are recorded into the Rhythm,
CV1 or CV2 part.
Since each part is separate, it is often useful to record a note-on into the Rhythm part while entering notes for
either of the CV parts. Use any of the CV selections to allow this for faster entering of Rhythm part
information.
If you wish to edit CV parts without recording new notes into the Rhythm part, set this parameter to
RHYTHM.
CV LINKS
The CV Links allows parameters for CV1 and CV2 to link (or use) the equivalent Rhythm parameter instead
of its own. CV Links can be selected using the Parameter knob, or Switch A(-) or Switch B(+). Press the TAP
Switch to toggle the current link selection On or Off. Parameters that are linked to the Rhythm will be
indicated as a solid white circle. Parameters that are not linked will be represented as an empty circle.
When no link is underlined, the display will show OFF or ON. Use the TAP Switch to toggle this value OFF
or ON. When OFF, any links set will be bypassed and each parameter will use its own parameter instead.
To clear all links, hold Switch A(-) and press the TAP Switch. To set all links, hold Switch B(+) and press the
TAP Switch.