background image

850 REV04 REV DATE: 09/03/2014                                                                                                                                                         

Page 

8

 of 

16

 

 

 

4.0 Prism Back Installation Instructions

 

 

5. 

To Install the Prism Back onto the back mounting plates please refer to the

 

Instructions and diagram (see Fig. 5 below).

 

Step 1: 

Insert the upper mounting plate into hooked slot on the top of

 

the back mounting plates.

 

Step 2: 

Ensure that the LT detent latch is in the closed position.

 

Step 3: 

With the upper pins in place, snap lower pins into the latch mechanism

 

at the bottom of the back mounting plates.

 

 

6. 

In order to install the longer Mounting Pins, first remove the outer cover

 

from the back.

 

 

! PLEASE NOTE 

 

Our Standard Prism Back can be adjusted to accommodate wheelchair seat frame sizes up to 2” 
wider than the actual back width. Each Prism Back is shipped with the standard mounting pins 
installed. A set of longer pins for 1” wider and 2” wider seat frames can be purchased separately. 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

                                                                                                                                                                                             

 

UPPER MOUNTING PIN 

LOWER MOUNTING PIN 

Содержание Prism BASIC

Страница 1: ...850 REV04 REV DATE 09 03 2014 Page 1 of 16 PRISM BACKS BASIC ULTRA TRUEFITT AIR BACK AND SUPER BACK FOR KIDS 850 REV04 REV DATE 09 03 2014...

Страница 2: ...equired Page 4 5 3 0 Before Installation Page 5 9 4 0 Prism Universal Hardware Installation Instructions Page 10 5 0 Disengaging the Prism Back Page 11 6 0 Head Neck Support Attachment Page 12 7 0 Tru...

Страница 3: ...Cane Clamps 4 Cane Inserts 6 Depth Recline Adjustment Screws 6 Cane Clamp Screws 2 Backing Plate 2 0 Tools Required Wrench 1 2 Allen Key 3 16 Tape Measure Ruler Mounting pins on the chair back Adjusta...

Страница 4: ...sition see Fig 1 below By altering the orientation of the Cane Clamps with the Back mounting Plates the hardware can be positioned to provide a rear most mounting position for the back if desired see...

Страница 5: ...lamp Screws 3 per clamp in order to open the clamp enough to fit around the back posts Install clamps inserts if required 3 Starting on one side position the Cane Clamp at the desire height on the bac...

Страница 6: ...tions Warning DO NOT install this equipment without first reading and understanding this instruction booklet If you are unable to understand these instructions contact a healthcare professional dealer...

Страница 7: ...lower adjustment slots are provided on the Prism Hardware Back Mounting Plates to allow alternate mounting heights when back post obstacles are encountered Using the Alternate Mounting Slots will inc...

Страница 8: ...sed position Step 3 With the upper pins in place snap lower pins into the latch mechanism at the bottom of the back mounting plates 6 In order to install the longer Mounting Pins first remove the oute...

Страница 9: ...htening nuts Standard Mounting Pin 1 2 Longer Mounting Pin Standard Mounting 1 Longer Mounting Pin Pins Prism Back Front View 8 Check that the fit and alignment of the back is correct 9 Fully tighten...

Страница 10: ...downwards on the left mounting plate until the ball plunger engages the latch open position 2 Push the release lever on the right mounting plate 3 Lower mounting pins will automatically ejected from t...

Страница 11: ...ver and determine which set of holes to use to attach the adaptor bracket The Bracket may be shifted 1 5 left or right depending on the user requirements 2 Close the cover and carefully punch 2 holes...

Страница 12: ...at the space next to the cube to be cut or carved 5 Trim each cube to the desired length using a sharp knife or scissors foam cutting saw works best 6 Reinstall trimmed foam blocks onto the aluminium...

Страница 13: ...all connections remain secure Cover USE mild detergent and machine wash cold using gentle cycle DO NOT USE fabric softeners or bleach DO NOT machine dry air dry in shady area PLEASE NOTE The cover is...

Страница 14: ...thout our prior consent The defective unit or parts must be returned for warranty inspection within thirty 30 days of the return authorization date Future Mobility Healthcare Inc will issue a return a...

Страница 15: ..._ Street Address _________________________________________________ City Country Postal Code ________________________________________ Telephone _______________________________ Purchased Date __________...

Страница 16: ...850 REV04 REV DATE 09 03 2014 Page 16 of 16...