51833575_V_1_0.DOC
23/45
Occupation of the DIP-switches:
Device 1 - channels 1-4
On
Off
DMX-starting
address
Projector number
& channels
Off
Device 2 - channels 5-8
On
Off
Device 3 - channels 9-12
On
Off
Device 4 - channels 13-16
On
Off
Device 5 - channels 17-20
On
Off
1
2
4
8
16
32
64 128 256
DIP-switch no.
1
2
3
4
5
6
7
8
9
Setting the DMX-
starting address:
Now you can start operating the WL-250 via your lighting controller.
DMX-protocol
Control channel 1 -– Magenta
DMX-value
Feature
0-255
Magenta (0=white, 255=magenta)
Control channel 2 – Yellow
DMX-value
Feature
0-255
Yellow (0=white, 255=yellow)
Control channel 3 – Cyan
DMX-value
Feature
0-255
Cyan (0=white, 255=cyan)
Control channel 4 – Shutter/Dimmer
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!