00114770.DOCX, Version 1.1
26/32
Menu structure in Stand Alone Mode
Default highlighted in gray
Mode
Display
Function
DMX
CHANNEL
ADDR: 001 ~ 512
Setting DMX starting address
CH:02
Setting DMX channel mode
CH:10
CH:12
SLAVE
SLAVE
Slave-setting
SOUND
SENS: 00 – 31, 25
Microphone sensitivity
REP: 01 – 99, 03
Frequency of the loops (chaser in an endless loop)
FLOW
5 programs
SPEED: 01 – 99, 50
Speed of the programs
FLASH: 01 – 99, 00
Strobe-Effect with increasing speed
AUTO
SPEED: 01 – 99, 50
Speed of the loops
REP: 01 – 99, 03
Frequency of the loops (chaser in an endless loop)
PIXEL FLIP
ON
Chaser direction: from right to left 10 - 1
OFF
Chaser direction: from left to right 1 - 10
MASTER
DIMMER
000 – 255
Increasing brightness 0 – 100%
DIMMER
RESPON01
Dimmer speed 1 = LED
RESPON02
Dimmer speed 2 = Halogen
FIXTURE ID
Password 000-255
Passwort: 050
RDM ID 0000-9999
ETHERNET
PROTOCOL
ArtNet
IP ADDRESS
XXX XXX XXX XXX
SUBNET MASK
255.000.000.000
DMX UNIVERSE
000-255
Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the DMX
output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller to
the DMX input of the master unit.
Press the MODE button to select the SLAVE MODE. The devices set in this manner can now be controlled
by the master unit.
Please press the ENTER button to confirm and the MODE button to exit the Mode.
Selecting an internal program
Press the MODE button to select the internal program mode FLOW. Select P01 – P05 via the UP or DOWN
buttons.
Press the ENTER button to select speed and flash settings, respectively. You can select the desired values
via the UP or DOWN buttons.
Speed from 01 to 99, increasing.
Flash from 01 to 99, increasing.
Please press the ENTER button to confirm and to exit the FLOW Mode.