Sound control/setting microphone sensitivity:
Press the MODE button and choose sound controlled Mode (SOUND MODE).
Press the ENTER button. You can select the desired microphone sensitivity (SENS 00-31, increasing) via
the UP or DOWN button. Please press the ENTER button again to confirm.
The desired frequency of the loops (Frequency = REP 01-99) can be selected via the UP or DOWN buttons.
Please press the ENTER button to confirm and the MODE button to exit the sound controlled Mode.
Auto
In Auto Mode, the chasers are called up automatically in a continuous loop.
Press the MODE button to select the AUTO mode.
Press the ENTER button to select the desired frequency of the loops.
The desired frequency of the loops (Frequency = REP 01-99) can be selected via the UP or DOWN buttons.
Please press the ENTER button to confirm and the MODE button to exit the AUTO Mode.
Invert function
In this mode, you can change the chaser direction, from left
to right or from right to left.
Press the MODE button to select the PIXEL FLIP function.
Press the ENTER button. Press the UP or DOWN button to
select ON or OFF. This will change the flow direction.
Please press the ENTER button to confirm and the MODE
button to exit the Mode.
Dimmer intensity
Press the MODE button to select MASTER DIMMER and press ENTER.
You can select the desired brightness values 000 -255 via the UP or DOWN button.
Please press the ENTER button to confirm and the MODE button to exit the Mode.
Setting dimmer speed (step response)
Press the MODE button until the display shows DIMMER. Press the ENTER button.
You can select the dimmer speed: RESPON01 (response characteristics LEDs) or RESPON02 (response
characteristics of halogen lamps) via the UP or DOWN button.
Please press the ENTER button to confirm and the MODE button to exit the Mode.
RDM
With this function you can call up various parameter via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an
extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.