The lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve
light performance.
Strike the lamp and focus the light on a flat surface (wall). Center the hot-spot (the brightest part of the
beam) using the 3 adjustment screws "A, B, C”. Turn one screw at a time to drag the hot-spot diagonally
across the projected image. If you cannot detect a hot-spot, adjust the lamp until the light is even.
To reduce a hot-spot, pull the lamp in by turning all three screws "A, B, C” clockwise ¼-turn at a time until
the light is evenly distributed.
If the light is brighter around the edge than it is in the center, or if light output is low, the lamp is too far back
in the reflector. "Push” the lamp out by turning the screws "A, B, C” counterclockwise ¼-turn at a time the
light is bright and evenly distributed.
3.2 Beampath
3.3 Rigging the fixture
DANGER OF FIRE!
When installing the device, make sure there is no highly inflammable
material (decoration articles, etc.) in between a distance of min. 0.5 m.
CAUTION!
Make sure that the device is fixed properly! Ensure that
the structure (truss) to which you are attaching the fixtures is secure.
For fixing the projectors use the hole provided in the bracket. The hole in the adjustable mounting bracket
has a diameter of 10 mm.
For overhead use, fit a safety chain or cord.
3.4 Connection to the mains
Connect the fixture to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
Distance (m)
Diameter (m)
Beam
open
ing
(
m
)