![Future light sc-240 Scanner Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/future-light/sc-240-scanner/sc-240-scanner_user-manual_2352109014.webp)
14
- 4 control-channels:
Channel 1: Horizontal mirror-movement (Pan)
Channel 2: Vertical mirror-movement (Tilt)
Channel 3: Colour-wheel
Channel 4: Shutter, Strobe, Gobos
Housing
- Easy access to lamp and main components thanks to large opening cover and the projector‘s modular
construction.
Temperatures
Maximum ambient temperature
t
a
: 55° C
Maximum housing temperature
t
B
(steady state): 80° C
Dimensions and weight
- L x W x H:
470 x 280 x 160 mm
- Weight:
10 kg
8. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not
build up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular
cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably
throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER!
Disconnect from the mains before starting any
maintenance work
The front mirror objective lens will require weekly cleaning as smoke-fluid tends to building up residues,
reducing the light-output very quickly. The cooling-fans should be cleaned monthly.
The gobos may be cleaned with a soft brush. The interior of the fixture should be cleaned at least annually
using a vacuum-cleaner or an air-jet.
The dichroic colour-filters, the gobo-wheel and the internal lenses should be cleaned monthly.
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating (T 3.15 A, 250 V slow).
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
9. Appendix
We hope you will enjoy your SC-240. We can assure you that you will enjoy this device for years if you follow
the instructions given in this manual.
Should you have further questions, do not hesitate to contact your local dealer.
Please note: errors and omissions for every information given in this manual excepted. Every
information is subject to change without prior notice. Any claim due to missing or wrong information
in this manual is herewith excluded!
All rights reserved (including those of translations in other languages). No part of this user manual
may be reproduced or changed without written permission from the publisher.
© 11/99