Connection with the mains
Connect the device to the mains via optional power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Connection of the devices
Installation PPP-60:
Set up the metal frame (feet pointing downwards) at the desired position.
Insert LED lamp frame carefully into the metal frame. Please make sure that the cables are always pointing
downwards.
Now attach glass panel carefully onto the appropriate rubber ring in the metal frame.
Connecting several PPP-60:
Please use the enclosed screws to mount several panels. Every panel features 2 locking eyes at every side
of the metal fram in order to connect several panels.