Long
Long
Long
Long
Long
Long
Long
Long
Long
Long
Long
Long
Long
Long
Long
View the percentage power
of output 1. (Heating)
View the percentage power
of output 2. (Cooling)
Hand ( Manual )
Control
Read Peak
Process Value
Calibrate
A-D converter
Enter the manual control mode.
Allow to adjust the percentage value of
output 1 by using
or
.
or
or
or
or
or
or
or
Change the value of
security level for the
selected parameter .
Change the value of
security level for the
selected parameter .
Change the value of
security level for the
selected parameter .
Display the rest of
parameters according
to the standard access
sequence.
or
or
or
or
or
Calibrate the A-D and Enter the
Cold-Junction compensation
Enter the drift compensation code.
Calibrate the 0 20mA and Enter it.
~
Enter the status.
Enter the status.
Enter the status.
Enter the Selection.
Enter the Selection.
Enter the Selection.
Enter the updated
security level of ASP1.
Enter the updated
security level of RAMP.
Enter the updated
security level of DB.
Adjust the Cold-junction
compensation code.
(-19.9 42.7 count)
~
Adjust the drift
compensatio
~
Adjust the drift
compensation code.
(-6.6 6.6 count)
~
Select a proper status for Output 1.
:Output 1 ON
:Output 1 OFF
Select Lock or F ree for the Security Level 0.
:Protect (Lock) all the Level 0 parameters
:Allow all the Level 0 parameters to be adjustable.
Select Lock or F ree for the Security Level 1.
:Protect (Lock) all the Level 1 parameters
:Allow all the Level 1 parameters to be adjustable.
Select Lock or F ree for the Security Level 2.
:Protect (Lock) all the Level 2 parameters
:Allow all the Level 2 parameters to be adjustable.
View the maximum (peak) process value.
View the minimum (peak) process value.
5.4 FLOW CHART OF TOOL PROGRAMS
Define
protection
mode for the
status of
control and
alarm outputs
to ensure a
safe condition
while the
control fails.
Lock
parameters
Configure
Security
levels for all
parameters.
:Security LEVEL
= 0 :Put the parameter
in LEVEL 0.
= 1 :Put the parameter
in LEVEL 1.
= 2 :Put the parameter
in LEVEL 2.
Reset the maximum and
minimum process values.
Reset the maximum and
minimum process values.
000 100%
~
**
(No function with FDC -9200.)
(No function with BTC -9200.)
**
**
**
Select a proper status for Alarm 1.
:Alarm 1 ON
:Alarm 1 OFF
**
Select a proper status for Alarm 2.
:Alarm 2 ON
:Alarm 2 OFF
**
Select a proper status for Output 2..
:Output 2 ON
:Output 2 OFF
**
Page 6