8. Miscellaneous
Reference values for external probe (CTN 10k
Ω
).
-10 °C / -14 °F
~55k
25 °C / 77 °F
~10k
0 °C / 32 °F
~32k
30 °C / 86 °F
~8k
10 °C / 50 °F
~19k
40 °C / 104 °F
~5,3k ohm
20 °C / 68 °F
~12,5k
These values must be verified with an ohmmeter when the probe is disconnected.
THERMAL SAFETY
In the case of overheating, a safety device automatically cuts the radiators
operation. After cooling the radiator will automatically reset.
If the failure persists, the safety cut off would permanently stop the device.
In this case, an after-sale service authorised by the manufacturer must check the
device. Contact your retailer or installer.
MAINTENANCE
Your radiator requires no regular maintenance, however, to ensure its good
operation:
Always disconnect the device from the mains before performing any cleaning or
maintenance operation.
Let it cool down before cleaning.
To avoid any risk of electrical shock, clean the unit with a soft, damp cloth to wipe
the outside of the radiator and remove dust and dirt cloth.
Do not use detergent, solvent, abrasive products or any other chemical product to
clean the radiator.
NEVER immerse the device in water or any other liquids.
You can use a vacuum or flexible brush to clean the air grilles. This maintenance
must be carried out regularly to ensure optimum performance. Ensure the radiator