We advise against installing the appliance under the windows, because it is
favoring the heat loss.
The radiator must be away, at a minimum distance of 15 cm from any
combustible material, curtains, furniture, chairs, etc.(Fig. 1).
Allow for a minimum distance of 1 m, from the front of the unit to any obstacles
(furniture, walls, curtains, for example) that could hinder its operation.
Also keep a minimum distance of 15 cm between the appliance and the side
walls and any other obstacles (walls, for example) that may affect its function.
Also keep a minimum distance of 35 cm on top the appliance free of obstacles
and a minimum distance of 15 cm from the floor.
WARNING: If this appliance is installed in a bathroom, it must be installed only
within Zones 2 or Outside Zones (Zone3), according BS 7671 Requirements
for Electrical Installations, Section 701. The installation of this appliance within
Zones 0 or 1 of a bathroom is totally prohibited. The figure 2 bellow is only for
information purposes, we suggest you contact a professional electrician.
- Minimum Distances -
Fig. 1
Zone 1: Appliances supplied to Safety Extra Low Voltage (SELV).
Zone 2: Electrical Appliances Class II – IP X4
Zone 3: Electrical Appliances protected by RCD 30mA
Fig. 2
WALL-MOUNTING
Fig. 3
Secure the appliance to the wall, and follow these instructions:
Mark the position of the holes' suspension supports, considering the distance
(58 cm) in relation to the floor and the distance between the supports to supply
the given model according to "Figure 4".
Make the holes and insert the plugs included in the fixing kit. Attach the
suspension supports to the wall with screws until the piece is sufficiently
secured "Figure 5".
The appliance is equipped with the following:
- 2 radiator's suspension supports (Figure 3).