3.  Weld the bar onto the unit so that both holes are vertical. (The straighter the bar is 
installed the better). 
4. Ensure the correct cable ends are at the control and sensor units.  Carefully route the 
sensor cable so the blade can swivel without stretching the cable.  Tie the cable with tie 
wraps (not included) so that the wire cannot be pinched. 
5.  Connect the sensor cable to the sensor box. 
 
With the sensor connected the calibration can now begin for the External sensor. 
 

External  Sensor  Calibration:  

-First enter the initial set-up screen (see page 3) and 
scroll to the sensor orientation screen.  Enter the 
number on the top of the sensor, which points to the 
forward direction of the machines travel.  

 

Once the sensor is oriented properly, the blade can be 
calibrated.

    To  calibrate  the  blade  we  must  exit  the  

initial  set-­up  screen  and  enter  the  menu  screen.  
    

-­Scroll  thru  the  menu  items  to  get  to  the  Control  axis  

screen.    This  menu  allows  the  user  to  indicate  which  
sensor  orientation  to  use  for  their  machine.    There  are  2  
options  either  Cross  rotation  (left  and  right)  or  
Fwd/Back  (front  and  back).    

  

-­  Next  press  the  menu  button  to  move  to  the  Zero  cal  

screen.  
-­Lower  the  blade  so  it  is  resting  on  the  ground.    
-­Mark  this  position.      
-­Press  the  up  arrow  to  store  this  position.    The  screen  

  Should  change  to  Zero  Cal  2.  

-­Turn  the  machine  around  180

ÛDQGUHVWWKHEODGHRQ

the  ground  in  the  same  location  as  marked  previously.  
-­Press  the  up  arrow  to  store  this  position.      
-­Your  LM5  is  now  calibrated  to  your  machine.  

  

  

  

  

  

  

LM5  Wiring:  

  

The  external  sensor  comes  complete  with  power  and  sensor  cable.    The  sensor  cable  is  

30’  and  it  has  a  power  hook-­up,  which  extends  18’.    The  power  wire  has  a  1  amp  fuse  in  series  to  
be  attached  to  the  machines  battery.      
  
The  pin  outs  for  the  control  box  to  sensor  cable  is  as  follows:  
  

Control  box     

Sensor  box         

Description    

  

Pin  1     

  

Pin  2     

  

power  (+12  –  30Vdc)    

  

Pin  2     

  

Pin  4     

  

Can  high  

  

Pin  3     

  

Pin  6     

  

Can  low  

  

Pin  4     

  

Pin  8     

  

machine  ground  

    Sensor                1     Forward                                                                                                  
       16.7%                                      Next                              

  

 
INT        

 

  

  

    Zero    Cal  .1                                                                         
        4.1%                                                    Next

  

    Zero  Cal  .  2                                                                         
        4.1%                                                    Next

  

  Control      axis                      
    Cross                                                    Next                                                        

  

 
INT        

 

  

  

Отзывы: