This screen is required to calibrate the LM5 to the terrain slope
your equipment is situated on. This is described further under
the calibration part of the manual.
The LM-5 is designed with a fast response time. This fast
response also reflects machine acceleration. Either vibrations
or accelerations can cause erratic grade control.
To reduce these false signals, it will be necessary to ‘slow
down’ the sensor to some degree. Select the fastest filtering
level that produces stable machine control.
This is the language menu. By selecting the up arrow you have
the option to change to French language.
Information splash service screen.
Initial Set-up Screen
By pressing the power and up buttons simultaneously the
initial calibration tree is entered and the following menus are
displayed.
Sensor Emulation
: Internal Use Only
This enables the internal sensor to communicate for
calibration. Disregard this screen using the menu button.
Sensor Orientation:
This menu allows for orientation of the sensor in regards to the
machines forward travel. When using an external sensor enter
the number on the top of the sensor, which is pointing in the
forward travel of the machine. For internal sensors the
configuration should be set to 1 - Forward. The menu defaults
back to main screen after 15 seconds.
Backlight:
This screen allows for backlight brightness. Select up or down
arrows to change. Select Default for factory setting. This
screen will change back to main menu after 15 second.
Final menu screen. Hold power off for 2 seconds to power
off.
Zero Cal .1
!
4.1% Next
Sensor Emulation
"
6.7% 4.9%
"
INT
Sensor 1
#
Forward
"
16.7% Next
INT
English
Next
G o o d b y e !
LATEC Instr. Inc
519235-4585 Next
INT
Back Light 150
Default Next
INT
Fast - - - I - - - - - - Slow
Filtering Next