LM5 Overview
The LM5 can be operated as a standalone instrument. Complete with 4 alkaline “AA” batteries
the LM5 will operate on full power for at least 3 days. The LCD panel back light does go out
after 20 seconds when not in use in order to conserve energy. If using the LM5 with an external
sensor it
must
be connected to an external battery.
Note: The LM5 is not programmed for auto shut-off. It is recommended user turn off the
unit when not in use.
The LM5 is also expandable to include a remote sensor. This sensor can be installed on moving
parts such as blades, buckets and forks etc. depending on the application. The Menu will change
to “EXT” when cable is connected.
Menu Options
When you first power up the LM5, the display will briefly
show the product version. Then the following; Desired grade
selection (top left) Real-time grade (top right) Internal vial
(INT) or External Sensor (EXT) and battery percentage (if
internal battery is being used)
Selecting the Menu button will allow the user to scroll thru the
various functions and features of the LM-5. Any changes
made to the menu items will be saved automatically when you
scroll thru to the next menu item
The first menus item is for selecting the backlight
configuration. Select the Flip button to enable or disable the
backlight option. *Note: Battery life for time enabled is rated
for 200 hours and disabled 12 hours of battery life.
Select Next for following menu
Using either arrow keys you can turn the Horn option on or
off.
Select Next for following menu
If horn is enabled the dead band grade settings can be
changed. Alarm will sound when you go past the dialed in
grade plus this offset. (ex. If grade setting is set at 0% and
dead band is set at 1.0% the alarm will sound at any grade
+1% and at any grade less than -1% slope)
This menu allows the user to indicate which sensor orientation
to use for their machine. There are 2 options either Cross
rotation (left and right) or Fwd/Back (front and back).
0.1 %
3.4%
!
INT 100%
INT
Horn
OFF
Next
INT
Alarm dead band
Grade 1.0 %
INT
Back Light Timer
Enable Next
INT
Control axis
Cross Next
INT