background image

Warning display

The function select switch 
dial screen can be dis-
played from this screen.

< NO SW >
If function’s ON/OFF switch 
is not selected, <NO SW> 
is displayed. 

89

Fu

nc

tio

n

Throttle Mode "TH MODE"

Idle-Up 

"

IDLUP

"

This is a function select switch dial function. The idle up switch must be set. 
This function is used to improve engine starting performance by raising the idling speed 

when starting the engine of a gasoline car (boat). It is also effective when you want to 

eliminate any braking effect when the power is turned off during running, due to the 

effect of your gear ratio setting and choice of motor when operating an electric car. 

However, considering safety, and to prevent the motor from rotating instantly when the 

power was turned on, the MC950CR, MC851C, MC602C, MC402CR, and other Futaba 

MC (Motor Controllers) will not enter the operation mode if the neutral position is not 

confirmed. When using the MC950CR, MC851C, MC602C, MC402CR, or other Futaba 

MC, confirm that the MC is in the neutral position and the set is in the operation mode 

before setting the idle up function switch to ON.

The throttle neutral position is offset to the forward side. There is no linkage locking, 

etc. because there is no change near the maximum operation angle even when the neu-

tral position is offset by this function.

Operation

(Preparation)
- Use the function select switch dial to select the switch. 

1

(Idle-Up rate)

Select the setting item "IDLUP" using the (JOG) button. Use 
the (+) and (-) buttons to set the Idle-Up rate.

2

When completed, return to the MENU screen by moving the 

cursor to the positions other than SW/DIAL and pressing the 
(JOG) button

 Idle-Up function adjustment

Adjust button

- Adjust with the (+) and (-) but-

tons.

- Return to the initial value "0" by 

pressing the (+) and (-) buttons 
simultaneously for about 1 sec-
ond.

Idle-Up rate (IDLUP)

 D50 ~ D1, 0, U1 ~ U50

  Initial value: 0
  "D": Brake side
  "U": Forward side

If the power switch is 

turned on while the 

idle-up switch is on, an 

audible alarm will be 

heard. Immediately set 

the Idle-Up switch to 

OFF. 

While this function is ON, the LED blinks. 

Operation Display 

The function select dial function can control the Idle-up rate with digital dial or digital 

trim. 

Dial / Trim Setting 

Содержание T4GRS-24G

Страница 1: ...can be turned on and off and flashed in step with steering and throttle operation as well as being turned on and off by switch The flashing speed cycle can also be set For instance the LED can be flas...

Страница 2: ...nction to be controlled for example throttle 3 ON OFF type setup Select the setting item TYPE using the JOG button up or down operation Use the or button and select the type of LED lighting Normal ON...

Страница 3: ...tle stick Throttle servo neutral position SXNT This function allows selection of the forward side and brake reverse side operation ra tio from 7 3 or 5 5 by changing the neutral position of the thrott...

Страница 4: ...al position and the set is in the operation mode before setting the idle up function switch to ON The throttle neutral position is offset to the forward side There is no linkage locking etc because th...

Страница 5: ...ects neutral brake side operation Effect of set value of other functions on neutral brake Neutral Brake NTBRK This is a function select switch dial function The neutral brake function ON OFF switch mu...

Страница 6: ...ated If the servo was operated at the wrong setting you may lose control of the car boat Adjust button Adjust with the and but tons Return to the initial value by pressing the and buttons simultaneous...

Страница 7: ...arious optional servo extension cords according to the distance between the transmitter and ESC The last data read from ESC to T4GRS or the last data written from T4GRS to ESC is saved to the T4GRS Si...

Страница 8: ...formed normally Check the T4GRS and ESC connection and the battery connection to ESC and the ESC power switch and repeat steps a b In addition if NO DATA is displayed on the T4GRS screen WRITE can not...

Страница 9: ...ency This setting can set the brake PWM frequency MIn which sets the frequency when the load is small is set to the high frequency side large value when extension is desired after straight away and cu...

Страница 10: ...Link software Brake Max Duty This setting can set the braking force between the neutral point and Max brake point The larger this value the greater the braking force When set to 0 the brakes are not e...

Страница 11: ...Hz 30kHz 30000Hz Same as Link software PWM frequency at Max load MAX sets the PWM frequency at maximum load at the output cur rent limit value set by Current Limiter CLM CURRENT LIMIT 50A 500A Same as...

Страница 12: ...V CANCEL BRk REV Same as Link software Reverse Cancel When set to BRk reverse operation is disabled DBA DEAD BAND 2 s 50 s Same as Link software Dead Band This sets the range neutral point range over...

Страница 13: ...o mode Lead Angle mode Lead angle Yes The output can be increased by setting a lead angle Depcompleted on the set value the motor may be damaged so increase the lead angle value in steps from a small...

Страница 14: ...oftware side Boost Angle rpm setting Page2 When using in races in which the lead angle setting function is inhibited by the ESC set LAU LEAD ANGLE USE to OFF The LAU setting has priority over TBM TURB...

Страница 15: ...battery display Therefore use this function when there is ample battery capacity remaining Note Since the receiving side writes the new contents of the currently selected model memory always check the...

Страница 16: ...er and buttons simultaneously The message RCV WAIT appears and count down begins Within 30 seconds press the transfer side TRANS trans mitter and buttons simultaneously If data transfer is not execute...

Страница 17: ...starts and stops each time the switch is pressed and accumulates the time between each start and stop When the count reach es 99 minutes 99 seconds the count returns to 00 minutes 00 seconds and is r...

Страница 18: ...et by alarm has elapsed automatically stops the timer The passing of time is indi cated by sounding of a buzzer beep each minute after starting Alarm Beep sounds at the set time Prealarm Alarm advance...

Страница 19: ...TIMER switch using the function select switch 1 Racing timer type selection Select the setting item TYPE using the JOG button Use the or button and set the racing timer type Timer selection TYPE UP U...

Страница 20: ...R as start Linking start only to the throttle stick Select the setting item RST using the JOG button and press the and buttons simul taneously for approximately 1 second When the set beeps and the sta...

Страница 21: ...taneously restarted Restart Linking start only to the throttle stick Select the setting item RST using the JOG button and press the and buttons simul taneously for about 1 second When the set beeps an...

Страница 22: ...for about 1 second When the set beeps and the status display switches from RST to blinking RDY the system enters the stick operation ready state When the stick is operated in the forward direction the...

Страница 23: ...h is operated If the timer is stopped after the set ALRM time has elapsed the final lap time is mem orized and the total time after the last lap is automatically written When the timer was stopped bef...

Страница 24: ...e battery alarm setting is dif ferent from that of the dry cell battery alkaline battery recommended Therefore always set the battery type to match the power source used If used with the incorrect set...

Страница 25: ...cklighting time Select the setting item LHT TM using the JOG button and use the and buttons to set the ON time When KEY is set at the preceding item this ON time be comes effective When completed retu...

Страница 26: ...iFe type battery FT2F1700BV2 2100BV2 NiMH5 Futaba MiMH type battery HT5F1800B DRY4 Dry cell battery alkaline battery recommended 4 batteries System Functions SYSTEM When completed return to the menu s...

Страница 27: ...e or button ENG Basic menu displayed in Alphabetic character Basic menu displayed in katakana character When completed return to the menu screen by pressing the JOG button When the neutral adjuster of...

Страница 28: ...automatically When each adjust ment point is within a fixed range correction is performed and COMPLETE fig 4 is displayed If an adjustment point is not within a fixed range correction is not performed...

Страница 29: ...een fig 2 state pull the stick back slightly then allow to return to neutral and press the JOG button whilst ensuring the stick is not touched Note that both the 5 5 and 7 3 neutral adjustment procedu...

Страница 30: ...sold separately to the S BUS2 connector of the R304SB E receiver The figure is an example of connection of a telemetry sensor The data of up to the fol lowing 3 types of sensors and the receiver power...

Страница 31: ...n Telemetry Function ON OFF Screen HOME screen Press Press Press Press Press Press Press Press Press Press p 117 p 120 p 118 The cursor on RT The cursor on RT Log Data Screen 116 Function Telemetry TE...

Страница 32: ...perature Sensor info RPM Sensor info Receiver voltage info Voltage Sensor info TELEMETRY ON OFF screen Temperature Sensor info RPM Sensor info Receiver voltage info Voltage Sensor info Telemetry Funct...

Страница 33: ...ternal power source drive bat tery voltage settings on page 1 of the sensor setting screen and temperature and speed settings on page 2 Pages 1 and 2 are switched by JOG button left or right operation...

Страница 34: ...ion and set the voltage at which the alarm begins to sound with the button or button The number of digits can be shifted using JOG button left or right operation When completed move the cursor to RT u...

Страница 35: ...om a minimum 0 1 second to a maximum 60 seconds Because the maximum count is 200 if the count is made 200 counts at 0 1 second intervals 20 seconds worth of data is acquired and if the count is made 2...

Страница 36: ...ximum 60 seconds with the button or button The maximum recordable time set by CYCL is displayed at END TIME shown below 3 Count alarm ON OFF Select the ALRM setting item using JOG button up or down op...

Страница 37: ...tton is operated up or down the list is scrolled 10 counts and each log data can be checked up to 200 counts 2 When completed return to the HOME screen by pressing the JOG button Log list check method...

Страница 38: ...a digital servo including BLS Series brushless servos Receiver s battery Matched to the ratings of the receiver and connected digital servo dry cell battery cannot be used Transmitter mode RX MODE Und...

Страница 39: ...different from that of the dry cell battery alkaline battery recommended Therefore always set the battery type to match the power source used Always set the battery type to N5 L2 especially when using...

Страница 40: ...ow posi tion when the transmitter is switched on Audible alarm Tone sounds 7 times and stops repeated Audible alarm Tone sounds 7 times and stops repeated LCD screen LCD screen MIX Warning MIX Warning...

Страница 41: ...y result in runaway or fatal crash Temperature Sensor SBS 01T RPM Sensor SBS 01RM Voltage Sensor SBS 01V When requesting repair Before requesting repair read this manual again and recheck your system...

Страница 42: ...e following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to whic...

Отзывы: