6HQVRU
9DULRXVWHOHPHWU\VHQVRUVVHWWLQJ
The telemetry sensor slot number and which sensor
is used in each slot can be changed in this screen.
Since the sensor in each slot is determined at
initialization and the same slot number is memorized
even for sensors sold separately, sensors can be
used by simply connecting them to S.BUS2. When
customizing the sensors yourself, perform the
settings in this screen.
[What is a slot?]
Servos are classified by CH, but
sensors
are
classified in units called
“slot”
. There are
slots
from
#1
to
#31
.
Altitude sensors, GPS sensors
and other data
sensor units may use
multiple slots
.
By the sensor which uses two or more slots,
the required number of slots is automatically
assigned by setting up a
start slot
.
When 2 or more of the same kind of sensor
are used, the sensors themselves must allocate
unused slots and memorize that slot.
*Three slots of altitude sensor are used.
*Eight slots of GPS sensor are used.
Sensor
The required
number of slots
The number which can be used as a start slot
Selling area
TEMP (SBS-01T,
SBS-01TE)
1slot
1
〜
31
Global
RPM (SBS-01RM,
SBS-01RO, SBS-
01RB)
1slot
1
〜
31
Voltage (SBS-01V)
2slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
Altitude (SBS-01/02A)
3slot
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
Current (SBS-01C)
3slot
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
S.BUS2 Servo sensor
(SBS-01S)
6slot
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 ,
2 4 , 2 5 , 2 6
GPS(SBS-01G)
8slot
8 , 1 6 , 2 4
TEMP125-F1713
1slot
1
〜
31
Europe
VARIO-F1712
2slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
VARIO-F1672
2slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
CURR-F1678
3slot
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
GPS-F1675
8slot
8 , 1 6 , 2 4
Kontronik ESC
8slot
8 , 1 6 , 2 4
ROXXY
5slot
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 , 2 4 , 2 5 , 2 6
JetCat V10
14slot
1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 5 , 1 6 , 1 7 ,
1 8
PowerBox
16slot
8 , 1 6