background image

2

3

TABLE OF CONTENTS

•  PROGRAMMING REMOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 4

•  ALARM FEATURES PROGRAMMING  . . . . . . . . . . . . . . . . . . . . . . . . . pg 5  

•  ADJUSTING THE SENSITIVITY LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . pg 8  

•  WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 9  

•  CENTRAL LOCKING DIAGRAMS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 11 

•  SPECIFICATIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 15   

FUSION CULTURE

There’s no point doing something if no one notices. We’ve always 

believed the way to make things happen is by getting noticed. From 

our product, to our demo cars, to our events, FUSION is about 

making some noise. 

Now you are ready. Step out of the shadows and announce you’ve 

arrived in a world where the old limits are left behind. Where 

technology is creatively combined with the latest in product 

innovation. Where new levels of entertainment are delivered with 

outstanding performance and quality. Our development team create 

distinctively different products; subwoofers, amplifiers, speakers and 

peripherals that redefine what can be done in car audio.

Leave the old behind and push the limits of what can be achieved in 

car audio. Make some noise.

For more information about FUSION Electronics visit our website at 
www.fusionelectronics.com 
or email [email protected]

RECORD YOUR PRODUCT DETAILS HERE:   

MODEL NUMBER _______________________________  DATE OF PURCHASE________________

AFFIX RECEIPT HERE

PROFESSIONAL INSTALLATION STONGLY RECOMMENDED

Installation Precautions:

1. Roll down window to avoid locking keys in vehicle during installation

2. Avoid mounting components or routing wires near hot surfaces

3. Avoid mounting components or routing wires near moving parts

4. Tape or loom wires under hood for protection and appearance

5. Use grommets when routing wires through metal surfaces

6. Use a voltmeter for testing and verifying circuits

V 2.0 

Содержание CE-SS200

Страница 1: ...CE SS200 INSTALLATION MANUAL VEHICLE SECURITY SYSTEM ...

Страница 2: ...stinctively different products subwoofers amplifiers speakers and peripherals that redefine what can be done in car audio Leave the old behind and push the limits of what can be achieved in car audio Make some noise For more information about FUSION Electronics visit our website at www fusionelectronics com or email technical fusionelectronics co nz RECORD YOUR PRODUCT DETAILS HERE MODEL NUMBER __...

Страница 3: ...G 1 Turn the ignition switch ON OFF 3 times within 15 seconds and leave in the OFF position on the 3rd time 2 Push the valet switch twice and hold on the 2nd push until one short chirp followed by one long chirp is heard then release the valet switch You are now in the alarm feature I programming mode 3 A Press and release the remote button corresponding to the feature 1 to be changed The siren wi...

Страница 4: ...oor locks unlocks Without ignition controlled door locks unlocks Exit Programming Turn ignition to ON position or wait for 15 seconds Three long chirps will confirm exit ALARM FEATURE III PROGRAMMING 1 Turn the ignition switch ON OFF 3 times within 15 seconds and leave in the OFF position 2 Push the valet switch 6 times and hold on the 6th push until three short chirps and one long chirp is heard ...

Страница 5: ...sitivity level by one each time a decrease is made the siren will respond with one chirp while 2 chirp s indicates the minimum sensitivity setting 5 Pressing button on the remote once will increase sensitivity level by one each time an increase is made the siren will respond with one chirp while 2 chirp s indicates the maximum sensitivity setting 6 Hit the bumper or strong metal part of the vehicl...

Страница 6: ...Door Lock Relay Green White Wire 30 Door Lock Relay Green Yellow Wire 87 Door Lock Relay 12V Green white Blue white Blue red Green red Green yellow Blue yellow 12V G reen w hite B lue w hite B lue red G reen red G reen ye llo w B lue yellow T o D oor U n lock C ontrol W ire T o D oor Lock C ontrol W ire Blue white Green white Door Lock Master Locking Switch Door unlock Green yellow Blue yellow A C...

Страница 7: ...ck Unlock OEM Door Master Lock OEM Slave Door Lock Switch 12V Lock Unlock To All Other Door Lock Motors Red White x OEM Driver s Door Lock Motor Blue Yellow Green Yellow 12V 12V 85 86 87 87A 30 6 Pin Door Lock Wire Harness x Cut Existing Unlock Wire X Lock Unlock OEM Door Master Lock Switch To All Other Door Lock Motor Red White OEM Door Lock Motor Blue White Green White Green Yellow Existing Lock...

Страница 8: ... VDC 16 VDC Operating temperature 40 C 80 C 40 F 176 F TX Frequency 433 92 M Hz POWER CONSUMPTION Indicator light flash output 15 Amp Door Lock 10 Amp Door Unlock 10 Amp Security system disarmed 15 mA Note Remote control range is dependant on weather conditions and alarm installation THE FUSION CE SS200 SECURITY SYSTEM COMPLIES WITH FCC This device complies with part 15 of the FCC rules Operation ...