2. HOW TO SETUP THE MENU
18
2.7
[Advanced Diagnostic] Tab (SCX-21 Only)
You can perform the advanced diagnostic test from the [Advanced Diagnostic] tab.
Note:
The [Advanced Diagnostic] tab is not used in the SC-33 and SCX-20. You can open the tab,
however all contents are grayed out and cannot be adjusted.
Advanced diagnostic test
Click the [Stat Diagnostic] button on the [Advanced Diagnostic] tab to start the advanced diagnos-
tic test. The following message appears.
The SATELLITE COMPASS
™
stops positioning while performing the advanced diagnostic test.
Also, you cannot abort the advanced diagnostic test until the test results are shown. Therefore, do
the test when position data is not required (in port, etc.). Click the [Yes] button to start the test.
The following table shows the test result of the advanced diagnostic test:
Test result
Remarks
ROM/
RAM
ROM
ROM test result (OK or NG).
RAM
Internal RAM test result (OK or NG).
TEST/
RESULT
Rate Gyro
Gyro sensor test result (OK or NG).
Acceleromtr
Acceleration sensor test result (OK or NG).
Port1 IO
Loop back test result for serial port 1 and 3. The serial port 2 cannot
perform the loopback test. Therefore, the test result for the serial port
2 alway shows “--”.
Note:
The loopback test tool is required to perform this test.
Port2 IO
Port3 IO
GNSS 1 RAM to
GNSS 4 RAM
RAM test result for GNSS 1 to GNSS 4 (OK or NG).
GNSS 1 ROM to
GNSS 4 ROM
ROM test result for GNSS 1 to GNSS 4 (OK or NG).
Yes(Y)
No(N)