2
-
+
BOW
12-24 VDC
NMEA
AD10
-
+
Å~
Sensor (top view)
Grounding
Black
Red
12-24 VDC
Figure 2 Battery connections to PG-1000
3. Turn the ship's mains switch on.
This sensor doesn't have power switch.
;;
;;
AUTO
TRUE
CALIB
STATUS
: On
: Blinking
: Off
: Status depends on settings.
;
;
About two minutes later
Figure 3 LEDs at power on
4. Confirm that the STATUS LED blinks.
Two minutes later it will light. If STATUS
LED doesn't blink and then light, suspect
sensor error. Reset power.
AUTO
TRUE
CALIB
STATUS
: On
: Status depends on settings
: Off
error
normal
Figure 4
1.2
Selecting Mounting
Location
The PG-1000 must be indoor on the horizon-
tal plane.
When selecting a mounting location, keep in
mind the following points:
• The ambient temperature must be between
-15
°
C and 55
°
C.
• Vibration at the mounting location should
be minimal.
• Install the sensor as far as possible from
power cable, ferrous materials.
• Install the sensor ship's center of gravity.
• Align the bow mark with the ship's bow on
the fore-and-aft-line.
1. Tentatively select the mounting location. Do
not fix it yet.
Ship's bow
Bow mark
Figure 1 PG-1000
2. Connect the PG-1000 to the battery as
shown in right.
Содержание PG-1000
Страница 1: ...INTEGRATED HEADING SENSOR MODEL PG 1000...
Страница 21: ......
Страница 22: ......
Страница 23: ......