background image

iiiiiiiiiiiii

 i

SAFETY INSTRUCTIONS

Confirm that the power supply voltage
is compatible with the voltage rating
of the equipment.

Connection to the wrong power supply 
can cause fire or equipment damage. 

Use the supplied power cable.

Use of a wrong power cable can cause 
fire or equipment damage.

CAUTION

Maintain the compass safe distance.

Standard compass

Steering compass

0.5 m

0.4 m

Turn off the power at the mains 
switchboard before beginning the
 installation.
Post a sign near the switch to indicate
it should not be turned on while the 
equipment is being installed.

Fire or electrical shock can result if the 
power is left on or is applied while the 
equipment is being installed.

WARNING

Safety Information for the Operator

CAUTION

Turns off the autopilot before selecting 
output data format.

The autopilot may turn the rudder suddenly.

Turns off the autopilot before aligning 
heading.

The autopilot may turn the rudder suddenly.

WARNING

Do not disassemble or modify the 
equipment.

Fire, electrical shock or serious injury can 
result.

Turn off the power immediately if water 
leaks into the equipment or the 
equipment is emitting smoke or fire.

Continued use of the equipment can cause 
fire or electrical shock.

Do not place liquid-filled containers on 
the top of the equipment.

Fire or electrical shock can result if a liquid 
spills into the equipment.

Safety Information for the Installer

Содержание PG-1000

Страница 1: ...INTEGRATED HEADING SENSOR MODEL PG 1000...

Страница 2: ...hi har a c ho Ni s hi nom i y a J apan Telephone 0798 65 2111 Telefax 0798 65 4200 Your Local Agent Dealer All rights reserved PUB No OME 72460 PG 1000 HIMA FIRST EDITION JUL 1997 H NOV 2 2000 Printe...

Страница 3: ...l shock can result if the power is left on or is applied while the equipment is being installed WARNING Safety Information for the Operator CAUTION Turns off the autopilot before selecting output data...

Страница 4: ...eading sensor is designed and constructed to meet the rigorous demands of the marine environment However no machine can perform its intended function unless operated and main tained properly Please ca...

Страница 5: ...1 6 Heading Alignment 6 1 7 Setting Output Data 6 2 CORRECTING MAGNETIC ANOMALIES 2 1 Controls and Indications 8 2 2 Turning the Power On Off 8 2 3 Automatic Distortion Compensation 9 2 4 Selecting O...

Страница 6: ...agnetic variation data NMEA CURRENT INDICATOR ex CI 1000 Course CSE 88 8 DISPLAY UNIT ex DD 2000 Heading ON OFF Optional equipment AUTOPILOT ex FAP 300 Heading Magnetic variation data Local Supply Mag...

Страница 7: ...Deviation Automatic correction of coefficients A B C D E by turning the ship manual by optional DD 2000 display unit I O Port Input 1 port Output 2 ports Interfacing Output FURUNO AD 10 format IEC 611...

Страница 8: ...S U S 6 1 x 4 0 8 0 2 0 8 0 0 0 2 2 r e h s a w t a l F 4 0 3 S U S 4 M 6 2 1 4 6 8 0 0 0 2 3 e l b a c r e w o P 9 1 0 0 S 2 2 0 0 0 9 0 1 0 0 0 1 4 y s s a e l b a C 0 0 1 7 0 0 0 F P S 6 A J M 7 3...

Страница 9: ...B STATUS On Status depends on settings Off error normal Figure 4 1 2 Selecting Mounting Location The PG 1000 must be indoor on the horizon tal plane When selecting a mounting location keep in mind the...

Страница 10: ...keys to gether to return to the normal mode The STATUS LED blinks while the sensor is be ing calibrated and lights steady when the calibration is completed Do not operate the sensor while the LED is...

Страница 11: ...Connect cables as shown in the Figure 8 Leave sufficient slack in cables for mainte nance and checking ease If cables run outside the bridge run them through conduit to protect them from corrosion BO...

Страница 12: ...ful all LEDs light Wait 30 seconds for the sensor to return to normal operation or press the TRUE key for quick return AUTO TRUE CALIB STATUS On Figure 12 LED status at successful correction Note 1 Do...

Страница 13: ...Press the and keys together more than two seconds All LEDs go off AUTO TRUE CALIB STATUS Off Figure 14 Note Complete the next step within 10 sec onds otherwise normal operation is restored 2 Set diff...

Страница 14: ...CALIB STATUS On current selection Off HDG HDT HDM HCC sentence HDG HDT HDM HCC Magnetic heading Magnetic variation value True heading Magnetic heading Compass heading Figure 17 LED and output sentenc...

Страница 15: ...elects output data format magnetic or true Turns on and off deviation corrections Figure 18 Front panel of PG 1000 2 2 Turning the Power On Off Note You may leave port after the STATUS LED begins ligh...

Страница 16: ...and COG course over ground in VTG 2 Set up magnetic variation manual or auto matic at the GPS navigator 3 Press the TRUE key more than two sec onds The TRUE LED blinks It lights when receiving data f...

Страница 17: ...ot be restored do not check inside the equip ment there are no user serviceable parts inside Any repair work should be referred to a qualified technician m o t p m y S y d e m e R d e r e w o p e b t...

Страница 18: ...ys to gether more than two seconds to escape from the test The STATUS LED blinks while the equipment is being calibrated and lights when the calibration is completed re turn to normal mode Do not oper...

Страница 19: ...posi tion referring to page 3 3 4 Displaying Program Version No When the equipment is powered on the pro gram no denoted by LEDs in binary notation is shown about 1 second For example LED state shown...

Страница 20: ...AP 1 PARTS LOCATION AND LIST CPU Board PG 1000 cover opened e m a N e p y T o N e d o C s k r a m e R d r a o B U P C 5 3 1 1 P 4 6 0 1 1 5 1 4 4 0 0...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Отзывы: