13. INSTALLATION
13-7
2) Put the transducer into water-filled plastic bag.
Press the transducer against the chosen site.
3) Turn the power on while pressing
key two
seconds approx.
4) Long-push
the
ESC/MENU
key to show the
main menu.
5) Rotate
the
RotoKey
™
to select [FISH FIND-
ER] menu.
6) Rotate
the
RotoKey
™
to select [FISH FINDER SETUP].
7) Rotate
the
RotoKey
™
to select [TRANSMISSION] and [LOW].
8) Press
the
ESC/MENU
key three times.
9) Press
the
HOME/CTRL
key.
10) Push the
RotoKey
™
to show the [FISH FINDER] display.
Check if the bottom echo appears on the display. If it doesn’t, do this proce-
dure until a suitable location is found.
11) After the mounting location is decided, turn off the power of display unit.
3. Remove the transducer from the plastic bag and wipe the face of transducer with
a cloth to remove water and any foreign material. Lightly roughen the face with
#100 sandpaper. Also, use the sandpaper to roughen the inside of the hull where
the transducer is to be mounted.
4. Wipe off any sandpaper dust from the face of the transducer.
5. Dry the face of the transducer and the hull.
Coat the transducer face and mounting loca-
tion with marine sealant. Hardening begins in
approx. 15-20 minutes so do this step with-
out delay.
6. Attach the transducer to the hull.
Press the transducer firmly down on the hull
and gently twist it back and forth to remove
any air which may be trapped in the marine
sealant.
7. Support the transducer with a piece of wood
to keep it in place while the sealant is drying.
It takes 24-72 hours to harden completely.
8. Turn the power on and change the menu setting as follows:
1) Long-push
the
ESC/MENU
key to show the main menu.
2) Rotate
the
RotoKey
™
to select [FISH FINDER] menu.
3) Rotate
the
RotoKey
™
to select [FISH FINDER SETUP].
4) Rotate
the
RotoKey
™
to select [TRANSMISSION] and [HIGH].
5) Rotate
the
RotoKey
™
to select [50kHz ECHO OFFSET] and [+20].
Plastic bag
Water
Hull plate
Transducer
Marine
sealant
Hull
Marine
sealant
Содержание GP-1870F
Страница 1: ......
Страница 44: ...1 OPERATIONAL OVERVIEW 1 28 This page is intentionally left blank...
Страница 118: ...9 MEMORY CARD OPERATIONS 9 6 This page is intentionally left blank...
Страница 142: ...11 CUSTOMIZING YOUR UNIT 11 6 This page is intentionally left blank...
Страница 172: ...13 INSTALLATION 13 24 This page is intentionally left blank...
Страница 186: ...APPENDIX 3 JIS CABLE GUIDE AP 14 This page is intentionally left blank...
Страница 188: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 16...
Страница 189: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 17...
Страница 190: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 18...
Страница 191: ...APPENDIX 4 INSTALLATION OF TEMPERATURE SENSORS AP 19...
Страница 196: ...6 Apr 2012 H Maki D 1...
Страница 197: ...6 Apr 2012 H Maki D 2...
Страница 198: ...6 Apr 2012 H Maki D 3...
Страница 199: ...6 Apr 2012 H Maki D 4...
Страница 200: ...D 5...
Страница 208: ......
Страница 209: ......