FURUNO
GP-1670/1870
SP - 2
E4476S01B-M
4.4 CAN bus PGN (NMEA2000)
Input 059392/904,
060928, 061184, 126208/992/996,
127245/250/251/258/488/489/493/496/505, 128259/267,
129025/026/029/033/038/039/040/538/540/793/794/798,
129808/809/810,
130306/310/311/312/313/314/577
Output 059392/904,
060928,
061184, 126208/464/992/996,
127258,
128259/267/275,
129025/026/029/033/283/284/285,
130310/312
5 POWER
SUPPLY
5.1 Display
unit
GP-1670
12-24 VDC: 0.5-0.3 A
GP-1870
12-24 VDC: 0.6-0.3 A
5.2 Rectifier (PR-62, option) 100/110/115/220/230 VAC, 1 phase, 50/60Hz
6 ENVIRONMENTAL
CONDITIONS
6.1 Ambient temperature
-15°C to +55°C
6.2 Relative humidity
93% or less at +40°C
6.3 Degree of protection
IP56