6. OTHERS MENU
6-15
Net Shooting Setting menu
The [Net Shooting Setting] menu sets up net shoot parameters. Selects [Net Shooting
Setting] on [Initial Setting] then push the left-click button.
Net Diameter
: Sets net diameter in increments of 10 meters. Setting range is 200 m
to 1000 m.
Tilt Interlock
: Turns on/off interlocking of diameter of net course mark with tilt angle.
Net Plot Corr-LYR1, 2, 3
: The movement of the net during net shooting is plotted us-
ing water current speed and direction fed from a current indicator. The current indica-
tor feeds that data for three depths (layers), thus net movement will be different at
each layer. Determine degree of difference among layers considering net, sea condi-
tions, etc. If 50% is set, for example, the net movement plot mark moves at
speed of 50% of water current speed.
Stabilization menu
The [Stabilization] menu compensates for the affects of pitching and rolling. Select
[Stabilization] on Initial [Setting menu] then push the left-click button. Requires a mo-
tion sensor.
Stabilization
: Turns stabilization on/off.
Note:
The default function of the
F9
key turns stabilization on/off.
Pitch Angle Cor
: Offsets the pitch angle error generated by the motion sensor.
Roll Angle Cor
: Offsets the roll angle error generated by the motion sensor.
Содержание FSV-35S
Страница 1: ...COLOR SCANNING SONAR FSV 35S OPERATOR S MANUAL www furuno com Model ...
Страница 12: ...SYSTEM CONFIGURATION x This page is intentionally left blank ...
Страница 88: ...4 NUMERIC GRAPHIC DATA DISPLAY 4 4 This page is intentionally left blank ...
Страница 118: ...7 RECORD RECALL OPERATION 7 8 This page is intentionally left blank ...
Страница 138: ...APPENDIX 1 MENU TREE AP 6 This page is intentionally left blank ...