8. MAINTENANCE, TROUBLESHOOTING
8-9
8.7 Error
Messages
This section describes the more commonly seen error messages and the means
to restore normal operation. If normal operation cannot be restored, contact your
dealer for advice.
8.7.1
Equipment trouble messages
Messages in this category are prefixed with “TROUBLE:”.
Equipment trouble messages
Error Message
Meaning
Action
ANT power voltage
abnormality.
Antenna power voltage.
Have a licensed
radiocommunications
technician check the set.
Carrier power level.
Carrier power level too high or
too low.
Have a licensed
radiocommunications
technician check the set.
DISTRESS ALERT
UNIT Fault.
Trouble at Distress Alert
Unit/Received Call Unit IC-305.
Check that the IC-305 is
powered and connected to
the FELCOM.
DMC connection
abnormality.
Trouble at Distress Message
Controller DMC-5.
Check that the DMC-5 is
powered and connected to
the FELCOM.
EEPROM ERROR.
EEPROM trouble.
Contact a FURUNO agent
or dealer for advice.
ALARM UNIT
Fault.
Trouble at Alarm Unit IC-306.
Check that the IC-306 is
powered and connected to
the FELCOM.
Invalid MES ID, This
equipment is
defected. Please
contact FURUNO.
MES ID is corrupted.
Have a licensed
radiocommunications
technician check the set.
Synthesizer
UNLOCK.
Synthesizer unlock.
Have a licensed
radiocommunications
technician check the set.
Содержание FELCOM 15
Страница 1: ...INMARSAT C MOBILE EARTH STATION MODEL FELCOM 15 ...
Страница 96: ...3 FILE OPERATIONS 3 22 This page intentionally left blank ...
Страница 132: ...4 INMARSAT C COMMUNICATIONS 4 36 This page intentionally left blank ...
Страница 203: ...APPENDIX AP 37 Antenna unit ANT RF Board 16P0207 ANT B Board 16P0206 Antenna unit cover opened ...
Страница 204: ...APPENDIX AP 38 This page intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 210: ......