14
Entering transducer data by transducer specifications
To connect the transducers which are not programmed, do as follows:
Note:
The transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz cannot be connected to
the FCV-1150 because of noise.
1. At the XDCR Setting dialog box, select “XDCR Select” and press the
ENTER
key.
The following screen appears.
2. Press
T
to select “Manual”, and then press the
ENTER
key.
3. If a high frequency transducer is fitted, press
T
to select “HF Connection” and then press the
ENTER
key.
4. Press
S
to select “Connected” and then press the
ENTER
key.
5. Press
T
to select “Freq” and then press the
ENTER
key.
6. Press
T
or
S
to set the value for the frequency which is connected and then press the
ENTER
key.
7. Press
T
to select “Band width” and then press the
ENTER
key.
8. Press
T
or
S
to set the value for the band width and then press the
ENTER
key. If the band
width is not entered manually, it is automatically set to 1/10 of the transducer frequency.
9. If a low frequency transducer is fitted, repeat steps 3 to 8.
Note:
Leave the “Tx Power” at “Auto”.
10.Press and hold down the [
/BRILL] key to turn off the power.
3.3
Speed/Water Temperature Sensor Calibration
If the optional speed and/or water temperature sensor is connected, set up as follows:
1. Turn on the power and press the
MENU
key.
The main menu and sub-menu appears.
2. Press
T
to select “System” and “Club” and then press the
ENTER
key.
XDCR Type
Manual
Connected
Not connected