11
4. Press
T
or
S
to select necessary unit and then press the
ENTER
key to set.
• Depth: m, ft, fa, pb, HR (Japanese unit)
• Temp:
°
C,
°
F
• Speed: kt, km/h, mph
• Wind: kt, km/h, mph, m/h
• Distance: nm, km, sm
5. Press the
MENU
key. The following message appears.
6. Press any key. The transducer setting screen appears. Proceed to next section.
3.2
Transducer Data
Entering transducer data by transducer model
The following table shows the transducers programmed in the FCV-1150.
*: for ACCU-FiSH (Fish information display)
Type
Output (kW)
Tap
Type
Output (kW)
Tap
28F-8
1
B
50BL-24HR
3
D
28BL-6HR
2
A
50F-24H
3
B
28F-18
2
B
68F-8H
1
A
28BL-12HR
3
A
68F-30H
3
B
28F-24H
3
D
82B-35R
2
E
38BL-9HR
2
B
88B-8
1
D
38BL-15HR
3
D
88B-10
2
C
50B-6B
1
A
88F-126H
3
E
50/200-IT
*
(50 kHz)
1
B
100B-10R
3
E
50/200-1ST (50 kHz)
1
B
150B-12H
3
C
50B-9B
1
A
200B-5S
1
D
50B-12
2
A
50/200-1T
*
(200 kHz)
1
C
50BL-12
2
A
50/200-1ST (200 kHz)
1
A
50BL-12HR
2
B
200B-8B
2
C
50BL-24H
3
D
200B-12H
3
C
CAUTION