APPENDIX 3 ALERT CODES, MESSAGES & MEANINGS
AP-18
-
52001,44 HW STATUS NO-
TICE
Caution
Cat: B
Message: "RF-CONV:PLL UN-
LOCK"*
5
Meaning: PLL lock on the RF side of
the RF-Converter is unlocked.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the RF-Converter.
-
52001,45 HW STATUS NO-
TICE
Caution
Cat: B
Message: "RF-CONV:OUTPUT SIG-
NAL LEVEL ERROR"*
5
Meaning: Signal output from the RF
Converter is outside rating.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the RF-Converter.
-
52001,46 HW STATUS NO-
TICE
Caution
Cat: B
Message: "RF-CONV:INTPUT SIG-
NAL LEVEL ERROR"*
5
Meaning: Signal input to the RF Con-
verter is outside rating.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the RF-Converter.
-
52001,47 HW STATUS NO-
TICE
Caution
Cat: B
Message: "HPA:OUTPUT SIGNAL
LEVEL ERROR"*
5
Meaning: Signal output from the HPA
board is outside rating.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the HPA board.
-
52001,48 HW STATUS NO-
TICE
Caution
Cat: B
Message: "HPA:OUTPUT PEAK CUR-
RENT ERROR"*
5
Meaning: Peak current detected in the
signal output from the HPA board.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the HPA board.
-
52001,51 HW STATUS NO-
TICE
Caution
Cat: B
Message: "HPA:TEMP HIGH"*
5
Meaning: Excessively high tempera-
ture detect on the HPA board.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the HPA board.
-
52001,52 HW STATUS NO-
TICE
Caution
Cat: B
Message: "VSWR ERROR"*
5
Meaning: Abnormal VSWR detected
by the RF Converter.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the antenna.
83
52002,01 HW STATUS ER-
ROR
Warning
Cat: B
Message: "RPU FAN1 NO ROTA-
TION"
Meaning: Fan1 in the processor unit is
stopped or disconnected.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the processor unit.
84
52002,02 HW STATUS ER-
ROR
Warning
Cat: B
Message: "RPU FAN2 NO ROTA-
TION"
Meaning: Fan2 in the processor unit is
stopped or disconnected.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the processor unit.
85
52002,03 HW STATUS ER-
ROR
Warning
Cat: B
Message: "RPU FAN3 NO ROTA-
TION"
Meaning: Fan3 in the processor unit is
stopped or disconnected.
Remedy: Press the
ALARM ACK
key. Have a qualified technician check the processor unit.
ALR
Alert ID
ALF
Alert ID
Alert title
Priority &
Category
Alert description
Содержание FAR-2218
Страница 132: ...1 OPERATIONAL OVERVIEW 1 110 This page is intentionally left blank ...
Страница 176: ...3 TARGET TRACKING TT 3 36 This page is intentionally left blank ...
Страница 202: ...4 AIS OPERATION 4 26 This page is intentionally left blank ...
Страница 232: ...5 VIDEO PLOTTER OPERATION 5 30 This page is intentionally left blank ...
Страница 294: ......