3. MENU SETTINGS
3-5
3.2.3
How to enter offset values
1. Press
to select [Offset Data], and
ENT
key to show the [Offset Data] menu.
2. Select [Trim], and press the
ENT
key.
3. Enter the offset value for inclined angle, and press the
ENT
key (setting range:
-12.5 to +12.5°, +: rise at bow).
4. Press
to select [Heel], and press the
ENT
key.
5. Enter the offset value for the heel, and press the
ENT
key (setting range: -12.5 to
+12.5°, +: rise at port).
6. Press
to select [XDCR], and press the
ENT
key.
7. Enter the offset value if transducer is not installed perfectly with ship’s fore-aft line
(setting range: -60.0 to +60.0°). Measure the difference between ship’s fore-aft
line and the line on the transducer, and enter it.