1. INSTALLATION
1-14
18. Check that fore marks are aligned, and fasten hex. nut (17), spring washer (18)
and hex. bolt (19) tightly.
19. Fasten hex. nut (20), spring washer (21) and flat washers (22) removed at step 4
to stud bolt on the seachest cap.
The distance between the seachest cap (4) and flange (7) must be 5 mm.
How to open the gate valve
When you open or close the gate valve, unfasten two nuts shown below to rotate the
handle. Then, fasten nuts to fix the handle.
-M12 hex. nut (20)
-M12 spring washer (21)
-M12 flat washer (22)
Fore mark
(at the bottom
of the transducer)
5 mm
Flange (7)
Seachest cap (4)