![Furuno DRS4DL+ Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/furuno/drs4dl/drs4dl_installation-manual_2349561011.webp)
1. INSTALLATION
5
• The cable must be secured so no tension is applied to the connectors. To pre-
vent tension, create a loop in the cable close to the sensor and secure the loop
with cable ties, as shown in the figure below.
• Wrap the junction of the connectors with self-vulcanizing tape for waterproofing.
• Using a cable tie, fasten the cable to the mast, etc. at the neck of each connec-
tor.
6. Connect the LAN connector of the cable assembly to a LAN port on the FURUNO
Multi Function Display or Ethernet HUB.
7. Connect the power wires to the ship’s battery (12 VDC or 24 VDC).
• Red wire: Connect to the positive terminal. The red wire has the fuse holder.
• Blue wire: Connect to the negative terminal.
• Black wire: The black wire is a shielding wire for grounding.
Loop cable and secure loop with cable ties.
The minimum bend radius is 80 mm.
Wrap junction and connectors with tape.
Connect cables
Cable Assy.
LAN connector
Ethernet Hub
or
Multi Function Display
LAN cable
To antenna unit
Cable assembly
Shield
Distribution
switchboard
Ship's battery
(12 VDC /
24 VDC)
Blue
Black
Fuse holder
Red
Содержание DRS4DL+
Страница 25: ...D 1 ...
Страница 26: ...S 1 ...
Страница 29: ......
Страница 30: ......
Страница 31: ......