SP - 2
(6)
Horizontal Range
12 steps during 30 m to 1600 m
(7)
Vertical Range
12 steps during 10 m to 800 m
(8)
E/S Range*
5 steps during 10 m to 800 m
(9)
E/S Shift*
1000 m max.
(10)
Offcenter
4 point at Expand mode, according to the train setting
2 point at Slice mode, according to the tilt setting
(11)
TVG
Level(100 dB max.), Range(1000 m max.)
(12)
Clutter
Variable, Hue control
(13)
Elimination Interference
Correlation with before data
(14)
Audio Monitor
2 W, 4 ohms using external speaker SC-05WR(option)
*: Optional external E/S interface is required.
3. TRANSCEIVER
(1)
Frequency
60/162 kHz selected by internal settings
(2)
Output Power
0.8 kW(60 kHz), 1.5 kW(162 kHz)
(3)
Beamwidth
-6 dB,
(4)
Pulselength
0.2 to 10.6 ms, varied according to the range in use
(selected on the Menu)
4. HULL UNIT
(1)
Train Step
45
°
step by fast scan mode or 6
°
step by normal mode
(2)
Tilting
Horizontal mode
Tilt Range: +5
°
to 90
°
, Tilt Step: 1
°
step
Vertical Fan Mode
Tilt Range: 0
°
to +180
°
, Tilt Step: 6
°
(fast scan) or 3
°
(normal)
(3)
Transducer Travel
400 mm
(4)
Raise/Lower Time
10 sec approx. (24/32 VDC)
(5)
Allowable Ship
’
s Speed
18 knots or less
(15 knots during raise/lower operation)
5. POWER SUPPLY AND CONSUMPTION
(1)
Display Unit
24/32 VDC (20 to 41.6VDC), 140 W approx. or
100/110/200/220 VAC, 50/60 Hz , 1
(2)
Transceiver Unit
24/32 VDC (20 to 40 VDC), 50 W approx. or
100/110/200/220 VAC, 50/60 Hz , 1
(3)
Hull Unit
24/32VDC, 50 W approx. (150 W while traveling)
AC spec. set requires rectifier RU-1746B-2