7-5
7.5 Train/Tilt Test
This test checks the transducer training and tilting functions for
proper operation.
1. Turn on the power while pressing and holding down the
MENU key.
2. Select TRAIN/TILT TEST with the arrow keys in the sub
panel 2.
3. Press the MENU key to start the test.
4. To return to the SYSTEM menu, press the MENU key again.
5. To quit, reset the power.
** TRAIN / TILT TEST **
-- PHOTO SENSOR CHECK --
-- TRAIN CHECK --
-- TILT CHECK --
TRAIN
0
°
180
°
OK
OK
TILT
+10
°
90
°
190
°
OK
OK
OK
→
→
→
→
0
180
0
180
PULSES
1428
1449
1427
1451
NG
0
0
0
0
180
°
( CW)
0
°
( CW)
180
°
(CCW)
0
°
(CCW)
→
→
→
→
+10
90
190
90
PULSES
1206
939
919
1225
TEST COUNT =
NG
0
0
0
0
8
90
°
190
°
90
°
+10
°
EXIT : PRESS MENU KEY
This checks the photo sen-
sors which detect the refer-
ence angles for training
and tilting operations.
This checks the transducer
training operation. The four
digit figures show the num-
ber of pulses used to train
the transducer by 180.
If training is abnormal, NG
(No Good) count increases
by one.
This checks the transducer
tilting operation. If the num-
ber of pulses used to tilt the
transducer is abnormal, NG
count increases by one.
Figure 7-4 Train/tilt test results