2-4
Navigation aid connection
If your navigation aid has NMEA0183 or
FURUNO CIF data format, your own ship's
position in latitude/longitude, the range/bear-
ing to waypoint, ship's speed, heading and
course may be input to this radar, and be seen
in the bottom text area.
You will need the following cable (optionally
supplied) to make the connection.
Type
MJ-A6SPF0012-050
MJ-A6SPF0012-100
Code no.
000-134-424
000-133-817
Remarks
5 m
10 m
Twisted pair cable
6-pin MJ
6-pin MJ
Figure 2-9 Navigation aid connection
2.4 Fuse Exchange for 24/32
VDC Power Cable
The display unit is supplied with a 10A fuse
(F1351) fitted in the fuse holder on the rear
panel. This fuse is for use with 12 VDC power
supply. For 24VDC or 32 VDC power sup-
plies, please exchange the fuse with the 5A
fuse supplied.
CAUTION
Use the proper fuse.
Use of an improper fuse can damage the
equipment and void the warranty.
2.5 Checking the Installation
After completing the installation, it is a good
idea to recheck it to be sure all steps were
correctly done. Use the table below to check
the installation.
•
The signal cable is securely retained
against the mast or mounting platform and
is free of interference from running rig-
ging.
•
The cable gland or entry on the deck, if
provided, is waterproof.
•
The power connections to the battery are
of correct polarity.
•
The plugs at the rear of the display unit
are tightly fastened.
•
The fuse F1351 on the rear panel is 10A
(12V) or 5A (24V/32VDC).