C16AK0009 REV.1
SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016
pg. 3
3.
Installation Type “Fan-out”
Typical application of a fan-out consists of up to 24 fiber input cable conectorized with two
MPO 12 fiber female connectors and twenty four (24) 1.6-2mm single fiber distribution cables
connectorized with SC/UPC connectors.
Other configurations are available upon request.
1.
Complete wall installation per paragraph 2 “Wall installation Instruction”
2.
Unscrew two (2) screws and temporally remove the holding plate to loosen the plastic
retainers. Lay down incoming 1.6 or 2 mm diameter cables in the retainer’s grooves.
Assemble approximately six (6) cable assemblies per retainer. Start laying the cables
from the bottom retainer and work your way up to the top one. Don’t put the holding
plate on back yet
3.
Plug the cable connectorized ends (SC/UPC) into the adapters. Match the adapter number
with the appropriate cable number. Adjust the cable “free” length before tightening the
cable retainers
4.
Put the holding plate back and tight up the screws. The cables should not move if you
gently tug on the cable
5.
Cut the rubber grommet following the molded in notch until you reach the center of the
molded hole. Slide a 3 mm cable of the MPO connectorized cable assembly through the
opening.
6.
Connect the MPO end to the appropriate MPO adapter port labeled F1 or F2
7.
Secure the cable to the retaining “L” bracket with a cable tie
8.
Fill in the provided destination sheet and insert it into the document holder, located on the
inside wall of the cover
9.
Assemble the cover to the base