1 General 

  1.1   General product information

 

1.2   Cable  types

  1.3   Symbols of this guide

2  Tools Required

3  Part List

4  Supplementary kit

5  Installation splitter/point to point module

 

5.1   Slide in module

  5.2   Connect connectors to DLX adapters

  5.3   Connect connectors to full size  

 

   

hardened 

adapters

  5.4   Bring fibers to the organizer

  5.5   Close protection cover

 

6  Cable preparation

 

6.1   Loop  capacity

  6.2   Cable retention (TENIO CTU)

  6.3   Insert feeder loop to storage area

 

6.4   Gel  containment

 

6.5   Securing  cable

  6.6   Install tube guidance

7  Splice feeder to splitter/point to point  

 module

 

7.1   Organizer

 

7.2   End  cut

 

7.3   Mid  cut

8  Branch cable

 

8.1   Prepare  cable

  8.2   Connect branch cable to feeder cable

9  Close the closure

10 Mounting the closure

 

10.1 Wall mounting

  10.2 Pole mounting

 

Content

1   General

1.1  

General Product Information

CommScope’s Mini-OTE 200 closure is a gel sealed fiber optic enclosure designed for splicing, termination and pass-through cable requirements in 
fiber-to-the-X (FFTx) architectures.
The closure is available in 4,6, and 8 port versions DLX  and 4 and 6 port versions full size hardened adapters; the housing is available in 2 colors, 
black and gray.
The terminal is designed for use in wall, pole or handhole applications.
The closure has a maximum capacity of 24 splices, 2 trays of 12 splices each and contains an additional tray for fiber storage. The terminal housing 
provides loop storage for microsheath or loose tube cable.
The Mini-OTE 200 allows for butt configurations with 4 wrap-around ports for multiple combinations of looped feeder cable (Ø 4 - 15 mm) and 
branch-off cable (Ø 4 - 9 mm) where the feeder cables are positioned at the outside ports and the branch-off cables at the inside ports. TENIO 
cable attachment is included as well as an external cable fixation integrated on the housing to absorb external forces on the cable.

1.2  

Cable types

The Mini-OTE 200 is designed for microsheath or loose tube cables with an outside diameter up to 15 mm, and flat cable:

Feeder cable

Ø 4 -15 mm

Branch off cable

Ø 4 - 9 mm and flat (4.5x8.1 mm)

Fiber types include single fiber 250micron.

1.3  

Symbols for this guide

Note

Presents useful information related to Installation Guide contents, the references and data related to the product’s use, etc.

i

Caution

Describes situations where data loss and incorrect product operation may occur, and provides proper actions to take in these 
situations.

!

Warning

Describes a situation where product damage and user injury may occur, and provides proper actions to take in these situations.

Mini-OTE 200

I N S T A L L A T I O N   I N S T R U C T I O N

Mini-OTE 200

TC-1334-IP
Rev A, Mar 2017
www.commscope.com

Содержание Mini-OTE 200 Series

Страница 1: ...applications The closure has a maximum capacity of 24 splices 2 trays of 12 splices each and contains an additional tray for fiber storage The terminal housing provides loop storage for microsheath or loose tube cable The Mini OTE 200 allows for butt configurations with 4 wrap around ports for multiple combinations of looped feeder cable Ø 4 15 mm and branch off cable Ø 4 9 mm where the feeder cab...

Страница 2: ...ck ordering guide kit content 3 Raster with tube guidance storage lip 4 Raster with 3 blind plugs 5 Raster with rings Item Description 1 Extra CTU 2 Gel inlet 3 Pole mounting kit Item Description 6 CTU 7 Hose clamps 8 Tie wrap 9 Foam strip 10 Wall mounting kit 2 Tools required 3 Part list 4 Supplementary kit 1 3 4 5 6 7 8 9 10 2 Scissors Cutting pliers Stripping tools shaving tools cleaning alcoho...

Страница 3: ...point module DLX Full size hardened adapters Front position Back position Front position Back position Point to point module port 1 4 Point to point module port 5 8 Point to point module port 1 3 Point to point module port 4 6 Splitter module 1x4 port 1 4 Point to point module port 5 6 Splitter module 1x4 port 1 4 Splitter module 1x4 port 5 8 Splitter module 1x8 port 1 8 Fiber color code standard ...

Страница 4: ...ke sure the pigtail attached to the central adapter is positioned under the hook on the module Otherwise the pigtail can be squeezed between the hook on the module and the protection cover when closing the protection cover 5 3 Connect connectors to full size hardened adapters Remove the dust caps of the adapters and the connectors that need to be connected Connect the connectors to the correspondi...

Страница 5: ...hen click tube in holder at the left side of the top cover Take care tube is well positioned above hinge protection cover so it is not squeezed when you close the cover 5 5 Close protection cover Close protection cover Snap hooks Strip pigtails as marked on picture 2 3 cm above tube end stop and route 250µ fiber to top splice tray in the other part of the closure Fiber picker available in protecti...

Страница 6: ... 4 3 1 35 5 2 4 2 1 7 2 4 1 7 11 2 3 1 5 Microsheath 2 1 30mm 6 10 60mm 10 13 70mm 13 16 80mm 2 6 50mm 2 1 3 2 3 4 5 1 x 6 2 3 Dual strength member Remove one strength member and attach CTU to the side of the remaining strength member Follow the same instructions to attach the CTU as describe under 6 2 2 Central strength member 6 2 4 Coated strength member Remove coating around strength member ove...

Страница 7: ...oth CTU s before loop is stored under the basket Kinks in the tubes can occur 6 4 Gel containment Containment rings are required to contain gel properly If the cable is too small the gel inlet needs to be used instead of the rings For flat cable no containment rings nor gel inlet is required See table to select proper containment None Small containment rings Large containment rings Gel Inlet Feede...

Страница 8: ...the cable Click hard plastic ring in cavity above and under gel 6 5 Securing cable Cut a piece of foam enough to make 1 tour around the cable If cable is thicker than Ø10 mm secure the cable to the closure with a hose clamp if the cable is smaller than Ø10 or if it is a flat cable secure the cable to the closure with a tie wrap Hose clamp Tie wrap Ø10 mm Ø10 mm Flat Cable 6 6 Install tube guidance...

Страница 9: ...he inside slots B as shown on picture below Pigtails from the modules in the top cover are routed in slot C There is a possibility to route fibers from the first tray to the second and vice versa trough special designed slots in the tower 7 Splice feeder to splitter point to point module FEEDER FEEDER BRANCH BRANCH A B B C A ...

Страница 10: ... cross on tray black pigtail hardened ports white feeder fiber Store unused fiber in small storage tray In case of shaved fiber already stored in storage tray store dark fiber on the splice tray 7 3 Mid cut Put a mark on both sides of the tube in the marking area 250 area and shave the tube up to both marks 10 11 cm from jacket end Take out required feeder fibers and cut in the middle Bring feeder...

Страница 11: ...ranch cable Bring feeder fibers tubes already taken out before storing loop under basket to second tray Make fusion splice store SMOUV S and over length as standard practice Store unused fibers in storage tray unless uncut shaved fibers are stored on the storage tray then unused fibers must be stored on the splice tray 8 Branch cable B i Insert blind plugs in empty gel ports Small blind plugs are ...

Страница 12: ...ure as guidance to fix the bracket to the closure i 2017 CommScope Inc All rights reserved All trademarks identified by or are registered trademarks or trademarks respectively of CommScope Inc This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services This product is covered by one ore more U S...

Отзывы: