![Furukawa electric S178 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/furukawa-electric/s178/s178_user-manual_2349550078.webp)
Operating Instructions
6-6
z
The splice loss is estimated and displayed on the LCD monitor as shown in the
picture.
4. While in Pause status, pressing Menu key displays options available in the process. To
resume the process, press
again.
z
Menu: Display the Menu Screen.
z
Zoom: Zoom in on the fiber image.
z
Capture: Capture the fiber image and store it with the splice data.
z
Field Change: Switch the fiber view between X and Y.
♦
If an abnormality was detected in the process, the estimated loss is displayed with “>”
instead of
“=”, to indicate the error occurrence in the cycle. (Example: LOSS > 0.04dB)