8
+
Disconnect
Fuse\Breaker
Fuse
Rooftop Solar
Electrical Box
FSEB30JWL-BL
+
-
-
Rigid Solar Panel
FSFP16MW-BL
Battery
+
-
Temperature Sensor
C-FSCC60PW-A01
C-FSCC60PW-A02
FBF12A100E
MPPT Solar Charge Controller
FSCC30PW-BL
FSCC60PW-BL
System Connection Diagram
Optional
WARNING:
Electrical shock hazard! Do not touch bare conductors or other
potentially energized parts.
–
Any hardware used must be compatible with the mounting structure material to
avoid galvanic corrosion.
–
It is not recommended to use modules with different configurations (grounding,
wiring) in the same system.
–
Solar modules must be connected in series when using a Furrion charge
controller.
–
The current, voltage, and power characteristics of the solar panel(s) will vary
based on environmental criteria including temperature and solar irradiance.
–
To prevent cables and connectors from overheating, the cross section of the
cables and the capacity of the connectors must be selected to suit the maximum
system short circuit current (The gauge of system cables is determined by the
system designer or installer.).
–
The maximum number of solar panels that can be connected in series is
dependent on the voltage limit of the MPPT charge controller and the open circuit
voltage (Voc) of the solar panel(s) at the coldest anticipated cell temperature. The
maximum system voltages of Furrion FSCC30PW-BL MPPT controllers is 70V
and Furrion FSCC60PW-BL MPPT controllers 135V. The number of panels used
in different configurations are depicted as below.
MPPT Charge Controller
Max. Number of Solar Panels
FSCC30PW-BL
2
FSCC60PW-BL
4